My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19190
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19190
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 11:41:10 AM
Creation date
9/20/2018 11:32:05 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19190
Building Department - Name
DR HORTON INC
Address
6712 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Load Short Form Job: <br /> � wrightsoft� Date: Oct 10,2014 <br /> Entire House By: , <br /> Progressive Air Systems, Inc <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' • • <br /> For: DR Horton <br /> Lot 2 Blk 6 Silverado Ranch, Zephyrh'ills, FL <br /> � - • � • <br /> Htg Cig Infiltration <br /> Outside db(°F) 40 91 Method Simplified <br /> Inside db(°F) 70 75 _ Construction quality Semi-tight <br /> , Design TD (°F) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/Ib) 26 54 ' <br /> � HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB030""'�A Cond CH14N6030****A <br /> AHRI ref Coil FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling 22500 Btuh <br /> Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh <br /> Temperature rise 27 °F Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=31 °F <br /> Backup: <br /> In ut=6 kW Out ut= 21934 Btuh, 100 AFUE - <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> M bed 237 3345 3280 165 154 <br /> di ning 202 2812 3947 138 185 <br /> greatroom 257 3318 4133 � 163 194 <br /> M wic 49 744 338 37 16 <br /> wc - 25 372 169 18 8 <br />, M bath 135 1579 845 78 40 <br /> kitchen 146 170 1547 8 73 <br /> laundry 42 252 843 12 40 <br /> A/C closet 14 , 16 25 1 1 <br /> bed3 . 154 1615 1675 80 79. <br /> foyer 162 1679 1494 83 70 <br /> bath2 60 659 322 32 15 <br /> bed2 166 3751 2716 185 127 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .L wri htsoft@ 2on-occ-so,,:o��as <br /> ,.�. 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 <br /> �+� .onlWrightsoft Files\Express homesWria 4EAB.rup Calc=MJS House taces: N , <br />
The URL can be used to link to this page
Your browser does not support the video tag.