Laserfiche WebLink
FORM R405-2014 <br /> MANDATORY REQUIREMENTS - (Continued) <br /> � R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. <br /> ❑ R403.3 Mechan3cal system piping insutation(Mandatory}. Mechanical system piping capable of carrying fluids abave 145°F(41 aC} . <br /> or below 55°F(13°C)shall be insulated to a minimum of R-3., <br /> R403.3.1 Protection af piping Insulatlon. <br /> � RA03.4.1 Circulating hot water systems(Nlandatory). Girculating hoi water systems shal!be provided with an automatic ar readily <br /> accessibie manuai switch tnat can tum off the hot-water circu(ating pump when the system is not in vse. <br /> C) RR03.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have <br /> heat traps installed on 6oth the inlets and outlets. Euternal heat traps shall cansist of either a commercially available lieat trap or a <br /> downward and upward bend of at least 3�/z inches(89 mm)in the hot water distributian line and cold water Iine[ocated as clase as passible <br /> to the storage tank. <br /> � R403.4.4 Water heater efficiencies(idiandatory). <br /> � R403.4.4.1 Storage wa#er heater temperature controls <br /> . R403.4.4.7.1 Automatic controls. Service wafer heating sysYems shall be equipped with automatic iemperature coairols <br /> capable af adjustment fram the Iowesf ta the highest acceptabie temperafure setti�gs for the intended use.7he minimum <br /> temperature setting range shall be from 100°F to 140°F(38°C to 60°C). <br /> . R403.4.4.1.2 5hut dawo. A saparate swPtch or a clearly marked circuit breaker shall be provided ta permit the power supplied <br /> to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) <br /> of combustiean types of service water heating systems.to be turned off. <br /> p R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of <br /> Table C404.2 in Chapter 4 of the Florida Building Code,Energy Canservation,Commercial Provisions,for the type of equipment installed. <br /> Equipment used to provide heating tunctions as part of a combinafion system sha11 satisfy aIl stated requirements for the apprapriate water <br /> heating category. So(ar water heaters shall met the criteria Sectian R403.4.4.2.1. <br /> . R403.4.4.2.1 Solar water heating systems. Solar systems for domesYic hot water production are rated by the annual sofar energy <br /> factor af the system.The solar er�ergy factor afi a system shal!be determined fram the Fiorida Solar Energy Center Directory of <br /> Certified 5alar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methads for Solar Collectors, <br /> and SRCG Standard TM-1,5olar pomestic hloi Water System and Component Test Pratacoi,Gailectors irt installed salar water <br /> heating systems shou(d meet the fo!(owing criteria: <br /> 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and <br /> 2. Be insta(1ed at an orientation within 45 degrees af true sauth. <br /> p R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the <br /> Fforida Buiiding Code,Residential or Ffarida 8ui(ding Gode,fvlechartical,as applicable,or wiih other approved rr�eat�s of ventilation. <br /> Outdoor air intakes and exhausts shal(have automatic or gravity dampers that close when the ventilation system is nat operating. <br /> ❑ R403.6 Heating and caolirtg equipment(Ariandatory}. The following sections are mandatary for cooting and heating equipment. <br /> � R403.6.7 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the <br /> equipment loads calculated io accordance with ACCA Manua!J or other appraved heafing and cooling calculatian tnethociologies, <br /> based on bui(ding loads for the directiona(orientation of the building.The manufacturer and model number of the outdoor and <br /> indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design canditions <br /> described in Section R302.1.i7�is cade does nat allow designer safety factors,provisions for future expansion or ather factors <br /> which affect equipment sizing.5ystem sizing calculations shall not include loads created by local intermittent mechanical ventilation <br /> such as standard kitchen and bathroom exhaust systems. <br /> • Rd03.6.1.1 Caating eqnipment capacity. Goo(ing only equipment sha(I be se(ected so that its total capacity is not(ess than the <br /> calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in <br /> Section 403.6,or the closest available size pravided by the manufacturer's product lines.The corresponding latent capacity of the <br /> equipment sha(!not be less than the calculated latent(oad. <br /> 1013dl2017 i 2.59 PM EnergyGaugeC�USA-F(aRes2014 -Section Fi445.4.1 Com � Page 2 of 3 <br />