My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19243
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19243
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:35:55 AM
Creation date
9/21/2018 9:35:53 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19243
Building Department - Name
LENNAR HOMES LLC
Address
3111 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� } � • , <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575A sf ADS 2017 Builder Name: Lennar Homes <br /> street: 3111 Moulden Hollow Drive Permit offce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: � 2�3 <br /> Owner. l.ennar Homes .lurisdiction: 611�00 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft� <br /> b.Concrete Block-Int Insul,Extenor R=4.1 996.67 ftZ , <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1491.00 ft <br /> 6. Conditioned floor area above grade(ft� 2584 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ft2 <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor Dbl, U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor,. 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 71.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Fleat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14 Hot water systems <br /> 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Ed e Insulation R=0.0 1093.00 ft� EF:0.950 <br /> 9 b. Conservation features <br /> b.Floor Over Other Space R=0.0 1051.00 ft2 None <br /> c.other(see details) R= 440.00 ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.43 pASS <br /> Total Baseline Loads: 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.�1r1E;ST�?,.. .; <br /> this calculation are in compliance with the Florida Energy specifications covered by this � �.�y� _--.�O � <br /> Code. calculation indicates compliance �w`�,,,�''' _'-�;.���+� <br /> � �,� =aa. ��_ ±C' <br /> wit h t he Florida Ener Code. rar�,,,��,' rt€�,.°;;+`��, O <br /> 9Y . r y,. ..:�. :.� <br /> PREPARED BY: �aVe ����� Before construction is completed r� �� � .�. <br /> DATE: this building will be inspected for �.-Gu��'- , --�. -� _ <br /> compliance with Section 553.908 *. � �'--- ; �, <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � � <br /> Y fY 9� 9 P ��? �-. <br /> with the Florida Energy Code. C�Ij'y�.'t�� <br /> OWNER/AGENT. BUILDING OFFICIAL: <br /> DATE. �� ` DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house. <br /> 7/6/2017 6:48 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.