My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19243
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19243
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:35:55 AM
Creation date
9/21/2018 9:35:53 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19243
Building Department - Name
LENNAR HOMES LLC
Address
3111 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � ; <br /> FORM R405-2014 � <br /> _ -�. <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575A sf ADS 2017 Builder Name: Lennar Homes <br /> street: 3111 Moulden Hollow Drive Permit o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> , owner Lennar Homes Jurisdiction: 611600 <br /> � Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1491.00 ft� <br />' 6. Conditioned floor area above grade(ftZ) 2584 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N!A R= ftz <br /> 11.Ducts R ftZ <br />' 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=028 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 ' <br /> c. U-Factor: Dbl,U=0.56 33.33 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF.8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1051.00 ft2 None <br /> c.other(see details) R= 440.00 ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 74.43 pASS <br /> Glass/Floor Area. 0.068 Total Baseline Loads: 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and - �T�ST,��,� ,.. <br /> � .-.. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��'�` _;;'�b� ., <br /> Code. calculation indicates compliance , �'�+�,,,''; `=�-��,�`.�``�:�. . <br /> �ave A��G� with the Florida Energy Code. F• �rnr�'?��. �;•��ti, O <br /> PREPARED BY: t� Before construction is completed r� �; �� �0 <br /> DATE: this building will be inspected for � -1�„� �`�- : :�. <br /> compliance with Section 553.908 ' *., * <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. .� <br /> with the Florida Energy Code. 9 9 p �COTj�y���_ <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br /> 7/6/2017 6:48 AM Ener Gau eO USA-FlaRes2014 Section R405.4.1 Com liant Software Pa e 1 of 5 I <br /> 9Y 9 P 9 <br />
The URL can be used to link to this page