My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19244
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:37:13 AM
Creation date
9/21/2018 9:37:11 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19244
Building Department - Name
LENNAR HOMES LLC
Address
3221 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ri <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941A sf ADS Builder Name: Lennar Homes <br /> street: 3221 Moulden Hollow Drive Permit Office: Cl of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number �,�Z�C{� , <br /> Owner. �ennar Homes ,lurisdiction: 611600 � I <br /> Design Location: FL,Tampa County• Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Euterior R=4.1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftZ <br /> z <br /> Conditioned floor area below grade(ftZ) 0 11 cDucts R R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic, Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft= �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl, U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N!A ftz a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft� b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 61 81 pASS <br /> Glass/Floor Area. 0.081 Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ' D�eT�5TA?, •- <br /> this calculation are in compliance with the Florida Energy specifications covered by,this � "a_•� '�p <br /> ��y ii,; k-r?`., .1{!.. � <br /> Code. � � calculation indicates compliance �'��,,, � ,= �.��.s+ <br /> �aVe ���C� with the Florida Energy Code. !. rrnr�°�%-:.:;-t'��-;;:�`•��,�O� <br /> a:;..�:.... �. <br /> PREPARED BY: Before construction is completed f '' �. <br /> DATE. this building will be inspected for � -I�'�����'- -" � <br /> compliance with Section 553.908 *.. `•`��'. :- -� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,� • <br /> with the Florida Energy Code. �G'Oj3 ��� <br /> W�<.. <br /> OWNER/AGENT' BUILDING FFICIAL. � <br /> DATE: � DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 8/7l2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.