My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19244
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:37:13 AM
Creation date
9/21/2018 9:37:11 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19244
Building Department - Name
LENNAR HOMES LLC
Address
3221 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941A sf ADS Builder Name: Lennar Homes <br /> street: 3221 Moulden Hollow Drive Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family • Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= �: <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.UnderAttic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft2 �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A � ft� a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1936.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 61.81 pASS <br /> GlasslFloor Area: 0.081 <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �T�S�'.q?.. -._ <br /> this calculation are in compliance with the Florida Energy specifications covered by this ���'a� r�R,;�O� <br /> Code. calculation indicates compliance w'�„�'';� _;-'.��:�.�s+. <br /> �ave ���C� with the Florida Ener � Code. ti »�rr �� �` �"�� `�a�Q , <br /> 9Y `�`'�- ��� � <br /> PREPARED BY: Before construction is completed :� �-- ''�r ""� "' -• <br /> DATE. this building will be inspected for �' :`���i ° � <br /> compliance with Section 553.908 ' * � '�� : •:� <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. =1,� : •4 <br /> with the Florida Energy Code. COD�q��'��� <br /> OWNER/AGENT' BUILDING OF.FI AL: ' � <br /> DATE. DATE: '' " <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 8R/2017 2:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.