My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19249
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19249
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:51:55 AM
Creation date
9/21/2018 9:51:53 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19249
Building Department - Name
LENNAR HOMES LLC
Address
6635 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�, _; � <br /> FORM R405-2G14 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2421A sf ADS Builder Name: Lennar Homes <br /> street: 6635 Paden Wheel Street Permit Office: Cl of Ze hyrhills <br /> City,State,Zip: ,FL, Permit Number• l �� <br /> Ovuner. LennarHomes Jurisdiction: (11C O <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area r <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ftz <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2421.00 ftZ <br /> 6. Conditioned floor area above grade(ft� 2421 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft� <br /> 11.Ducts R ft2 <br /> 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 <br /> a. U-Factor: Dbl,U=0.54 140.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.58 64.00 ftZ 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 26.67 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. � <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> 8. Floor Types (2421.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF'0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2421.00 ft2 b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= �Z 15.Credits Pstat <br /> Glass/Floor Area: 0.095 Total Proposed Modified Loads: 77.04 pASS <br /> Total Baseline Loads: 77.37 <br /> I hereby certify that the plans and specifications covered by Review of the plans and :��'C��ST,q?,� ,_ <br /> this calculation are in compliance with the Florida Energy specifications covered by this "__��, .p . � <br /> v ��S' ii,; �_`-``.` *{+.. <br /> Code. calculation indicates compliance �w �,,, � - ?,,�.�``�:�, .; <br /> �ave ��G� with the Florida Energy Code. E+ rrn�,�:%%%.�;_:�;�;;;��rtiti=0 <br /> PREPARED BY: � ''�r '`��""' <br /> Before construction is completed � �� � � <br /> DATE: this building will be inspected for �.�1�� � �. <br /> compliance with Section 553.908 '.* � '�.:-. � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ' .� <br /> -�G, �5• ,, <br /> with the Florida Energy Code. Orj y�� <br /> i` <br /> OWNER/AGENT: --- BUILDING O FICIAL: <br /> DATE. DATE: ��� <br /> - Compliance requires certificatio by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is-not greater than 0.030 Qn for whole house. <br /> 8/11/2017 11:46 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.