Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19249
Building Department - Name
LENNAR HOMES LLC
Address
6635 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2421A sf ADS Builder Name: Lennar Homes 1 <br /> street: 6635 Paden Wheel Street Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: � <br /> owner �ennar Homes .lurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R_ �z <br /> 10.Ceiling Types (2421.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2421.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2421 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11 Ducts R ftz <br /> 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 <br /> a. U-Factor Dbl,U=0.54 140.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.58 64.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor• Dbl,U=0.56 26.67 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> S. FloorTypes (2421.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2421.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ffZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 77 04 pASS <br />, Glass/Floor Area: 0.095 Total Baseline Loads: 77.37 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _ �H�iST�q .. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��'�� _ ���p <br /> Code. calculation indicates compliance �r,,��''� r`=��=��;���, <br /> �. ., _'s a�a �` <br /> �ave �✓�G� with the Florida Energy Code. F+_ -rrrrr�"%::����';:��`ti O <br /> PREPARED BY: �w� • �, " � <br /> Before construction is completed "rs�i m• � ' � <br /> � Pl�`._ - . . "= C <br /> DATE: this building will be inspected for {�•��;�� �, <br /> compliance with Section 553.908 ' *, . � � - : .* <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. � <br />� with the Florida Energy Code. 9 9 p �G'Olj'y����. <br /> OWNER/AGENT' BUILDING F CIAL: <br /> DATE: DATE: � ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certifed factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br />� - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/11/2017 11 46 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 1 of 6 <br /> I <br />