My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19249
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19249
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2018 9:51:55 AM
Creation date
9/21/2018 9:51:53 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19249
Building Department - Name
LENNAR HOMES LLC
Address
6635 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2094 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2421A sf ADS Builder Name: Lennar Homes <br /> street: 6635 Paden Wheel Street Permit office: City of Zephyrhills <br />� City,State,Zip: ,FL, Permit Number. <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> i Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ftz <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ft2 <br /> I 3. Number of units,if multiple family 1 c.N/A R= g= <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (2421.0 sqft.) Insulation Area <br /> 5. Is this.a worst case? Yes a.Under Attic(Vented) R=30.0 2421.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 2421 b.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11.Ducts R ft2 <br />� 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rtn,AH:laundry 6 484.2 <br /> a. U-Factor Dbl,U=0.54 140.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.58 64.00 ft2 12-Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 26.67 ft� <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> 8. FloorTypes (2421.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2421.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= �2 15.Credits Pstat <br />' Glass/Floor Area: 0.095 Total Proposed Modified Loads: 77 04 '� <br /> Total Baseline Loads: 77.37 PASS � <br /> I hereby certify that the plans and specifications covered by Review of the plans and : �T��S�'r�7.. :� � <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��'4 ' �_��-�p � ' <br /> Code. calculation indicates compliance '�"���,��'' '"'��'��.�� �c+. <br /> �s: , <br /> /� /, with the Florida Energy Code. `ti 1r{rr��`?% ':�"�`';��"-�`�;,� I <br /> ��V� WI��YG �,.�...y. .� ' , <br /> PREPARED BY: � Before construction is completed , � <br /> DATE: this building will be inspected for � �I��;` ',.l' : � '� <br /> ���II--� <br /> compliance with Section 553.908 �., ` �' � �. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. 1,yC _ .: ��� <br /> with the Florida Energy Code. �D`{�.'�'' . <br /> OWNER/AGENT: BUILDING O FICIAL: <br /> DATE. DATE: - ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/11/2017 11 46 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.