Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2575A sf ADS 2017 Builder Name: Lennar Homes <br /> street: 3209 Moulden Hollow Drive Permit Office: Cl Ze�hills � <br /> City,State,Zip: ,FL, Permit Number: `� <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftZ <br /> � b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz <br /> 4. Number of Bedrooms 4 d•N�p' R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491 0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1491.00 ft <br /> 6. Conditioned floor area above grade(ft� 2584 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11.Ducts R ftz <br /> 7 Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor� Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtulhr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF.8.50 <br /> Area Weighted Average Overhang Depth: 1.190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2584.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1051.00 ftZ None <br /> c.other(see details) R= 440.00 ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 74.43 pASS <br /> Glass/Floor Area: 0.068 <br /> Total Baseline Loads: 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and : .��T���'.��,�`.; <br /> , this calculation are in compliance with the Florida Energy specifications covered by this .,y ,,�. �-T.�� �j�, ', <br /> Co de. ca lcu la tion in dica tes comp liance �;r,�,,T J''. ��,-•��� .r s+`. <br /> �,•y� �i ,Gx::i��+�'�A -.'C_ . <br /> �ave A/��G/ with the Florida Energy Code. F+ �tdrrr.�µT`�, •,,;r-�:;;�- titi 0 . <br /> PREPARED BY: t'tw�, « Before construction is completed � V ���.». - '�' a <br /> DATE. this building will be inspected for � .�`f=� �; <br /> compliance with Section 553.908 �:. ��.���� , : ;� <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. +C;• <br /> Y fY 9� 9 P � --�. <br /> with the Florida Energy Code. `CDp yy�`f��-- <br /> OWNER/AGENT BUILDING O�CIAL: <br /> DATE: DATE. <br /> - Gompliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifes as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house. <br /> 7/6/2017 6:48 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />