My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19305
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19305
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 7:38:44 AM
Creation date
9/24/2018 7:38:42 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19305
Building Department - Name
LENNAR HOMES LLC
Address
3209 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> r ' <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2575A sf ADS 2017 Builder Name: Lennar Homes <br /> �street: 3209 Moulden Hollow Drive Permit ottice: City of Zephyrhills <br /> City,State,Zip: ,FL, Pertnit Number: <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family � a.Frame-Wood,Exterior R=11.0 1264.00 ft� <br /> b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz <br /> 4. Number of Bedrooms 4 d•N�p` R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1491 0 sqft.) Insulation Area � <br /> a.Under Attic(Vented) R=30.0 1491.00 ft <br /> 6. Conditioned floor area above grade(ft� 2584 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ftZ <br /> 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 <br /> a. U-Factor: Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 71.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: ' Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftz a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1 190 ft. <br /> Area Weighted Average SHGC: 0.300 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2584.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Consenration features <br /> b.Floor Over Other Space R=0.0 1051 00 ftZ None <br /> c.other(see details) R= 440.00 ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 74.43 pASS <br /> Glass/Floor Area: 0.068 <br /> Total Baseline Loads: 74.43 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ` ��'SI�:$�',��,� ., <br /> • this calculation are in�compliance with the Florida Energy specifications covered by this ,�S' ,l�, ''`= �.` p� .� <br /> Code. calculation indicates compliance '�i,� -'' __-�`:�� �+ <br /> tQ _.i . =?a=,,'_�'. <br /> with the Florida Energy Code. � +�ui�'��. .;`:���;:���`�� � , <br /> �ave �GG�l�rcl� Before construction is com leted i� �� "°� � "` � <br /> PREPARED BY: p ' � <br /> D A T E: t h i s b u i l d i n g w i l l b e i n s p e c t e d f o r �.�`i���� -�, � <br /> compliance with Section 553.908 ` �. -�� . � <br /> I hereb certi that this buildin as desi ned,is in com liance Florida Statutes. <br /> with the Florida Energy Code. 9� 9 p � �Cap'yy�.`t'���� <br /> . <br /> OWNER/AGENT: BUILDING OFF GIAL: <br /> DATE. DATE. ���'y i , <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.070 Qn for whole house. <br /> 7/6/2017 6.48 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.