My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19306
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19306
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 7:39:53 AM
Creation date
9/24/2018 7:39:50 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
18-19306
Building Department - Name
LENNAR HOMES LLC
Address
3197 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, � <br /> Manual S Com liance Re OI"t Job: 2889A1 sf ADS <br /> p p Date: 7013012017 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br />� ' � - • � <br /> For: Lennar Homes <br /> . • • • . <br /> Design Conditions <br /> Outdoor design DB: 92.4°F ,� Sensible gain: 19987 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.4°F ' Latent gain: 2905 Btuh Entering coil WB 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 22891 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's PerFormance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 107% of load <br />� Latent capacity: 3780 Btuh 130% of load <br /> Total capacity: 25200 Btuh 110% of load SHR: 85% <br />' • • • <br />, Design Conditions <br /> Outdoor design.DB: 30.8°F Heat loss: 23100 Btuh Entering coil DB: 69.6°F <br /> i Indoor design DB: 70.0°F <br /> � , <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow� 800 cfm <br /> Output capacity: 21800 Btuh 94% of load Capacity balance: 33 °F <br /> Supplemental heat required: 1300 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity� 6.5 kW 96% of load Temp. rise: 50 °F <br /> Meets are all requirements ofACCA Manual S. <br /> ,,� wri htsoft' 2017-Oct-30 09:34:45 <br /> 9 Right-Suite�al Universal 2017 17.0.23 RSU05714 Page 1 <br /> � ...BA27UHE AH's\2889A sf template ADS 1.5-2ton.rup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.