Laserfiche WebLink
: , <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2889A1 sf ADS 2017 Builder Name: Lennar Homes 0036 <br /> street: 3197 Moulden Hollow Drive Permit o�ice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ftz <br /> b.Frame-Wood,Exterior R=11.0 1114.00 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ftZ <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2173.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 <br /> z � <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft <br /> 11.Ducts R �}_ <br /> 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 358 <br /> a. U-Factor: Dbl,U=0.54 96.00 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.56 64.00 ft2 �2•Cooling systems kBtu/hr Efficiency ' <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 � <br /> b.Central Unit 18.0 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency i <br /> d. U-Factor N/A ft' a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 17.5 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1 172 ft. <br /> Area Weighted Average SHGC: � 0.302 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2902.0 sqft.) Insulation Area EF�0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 672.00 ft2 None <br /> c.other(see details) R= 437.00 ftz 15.Credits Pstat <br /> Total Proposed Modified Loads. 84 94 pASS <br /> Glass/Floor Area: 0.067 Total Baseline Loads: 85.63 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 4Tk1E;S�;q?,� ., <br /> this calculation are in compliance with the Florida Energy specifications covered by this -�y� ' "_ � p <br /> Code. calculation indicates compliance ���;�;�''� "',�`;;.�� <br /> -�',.�=.��'�, <br /> /I w i t h t h e F l o r i d a E n e r g y C o d e. �F+ r�rir��'�.-.==�.�'°��:��„ O <br /> PREPARED BY: �G�l�� ��1'I�VI Before construction is completed r� '! " �' <br /> DATE. this building will be inspected for � �f�1��;�- -` - - :� - <br /> compliance with Section 553.908 " *�. :-�'� - � :* <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,!, _- _ _ ' �� ' <br /> with the Florida Energy Code. � -~��'p' �.�� � <br /> :i�VE:.. <br /> OWNER/AGENT: BUILDING OFF CI : <br /> DATE: DATE: �l � <br /> - Compliance requires certification by the air handler unit manufacturer that the airhandler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 10/13%2017 7:06 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />