Laserfiche WebLink
, , <br /> FORM R405-2014 • <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Pertormance Method <br /> Project Name: 2889A1 sf ADS 2017 Builder Name: Lennar Homes 0036 <br /> street: 3197 Moulden Hollow Drive Perrt,�t o��: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner: �ennar Homes .lurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ftZ <br /> b.Frame-Wood,Exterior R=11.0 1114.00 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ftZ <br /> 4. Number of Bedrooms 5 d.N/A R_ ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2173.00 ftz <br /> 6. Conditioned floor area above grade(ft� 2896 b.Knee Wall(Vented) R=30.0 140.00 ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R �Z <br /> 7 Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358 <br /> a. U-Factor Dbl,U=0.54 96.00 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 64.00 ftZ 12-Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 18.0 SEER:16.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 17.5 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.172 ft. <br /> Area Weighted Average SHGC: 0.302 14.Hot water systems <br /> 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftz b. Consenration features <br /> b.Floor Over Other Space R=0.0 672.00 ftz None <br /> c.other(see details) R= 437.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.067 Total Proposed Modified Loads: 84 94 pASS <br /> Total Baseline Loads: 85.63 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.TIi.E=S�,��,� '•�. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��'� = O <br /> Code. calculation indicates compliance �''��,,,��''� r`:�-�'�.�,`�+ � <br /> a �a 'C ' <br /> /,� with the Florida Energy Code. �� nu��';��;:,::��:;;,.� „ O <br /> PREPARED BY: �aV� �Wl��� Before construction is completed `�'" "" � <br /> D A T E. t h i s b u i l d i n g w i l l b e i n s p e c t e d f o r � ��°��T :� <br /> compliance with Section 553.908 ' -*��� - � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .� ' ,� ' <br /> with the Florida Energy Code. �' � �� ' <br /> � iM1T�. � <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: _ 2-/�'>� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 7:06 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />