Laserfiche WebLink
�', <br /> , <br /> FORM R405-2014 <br /> I FLORIDA EN�RGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> 0417 <br /> Project Name: 2421 B sf ADS Builder Na e: Lennar Homes <br /> street: 6659 Paden Wheel Street Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: i �v�� <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= �z <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2421.00 ft <br /> 6. Conditioned floor area above grade(ftZ) 2421 b.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R ft2 <br /> 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 <br /> a. U-Factor� Dbl,U=0.54 140.00 ftZ <br /> SHGC: SHGC=0.31 <br />, b. U-Factor Dbl,U=0.58 64.00 ftz 12•Cooling systems kBtu/hr E�ciency <br />� SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 26.67 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2420.2 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= �Z 15.Credits Pstat <br /> Total Proposed Modified Loads: 77.09 pASS <br /> Glass/Floor Area: 0.095 <br /> Total Baseline Loads: 77.37 <br /> , I hereby certify that the plans and specifications covered by Review of the plans and �'��:��'�7, --. <br /> a �<�._ t�` <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,. �4;� O:.��� <br /> ,�. ��., w-.�.... :.t+.. <br /> Code. calculation indicates compliance �.,�,,; _{ �.�� �.�n+. <br /> �,, �:„�s�.a��� {- .. <br /> /" with the Florida Energy Code. F+ .�iiu'.� :�. �,;;: . .��'-��, ;O <br /> PREPARED BY: �aV� f��f'IGVI Before construction is completed �r`� - ' ' "''"� "" "� <br /> DATE: this buildin will be ins ected for r r <br /> 9 P 7. .w:_.�;I;��._ .- � "' � <br /> .��., . <br /> compliance with Section 553.908 * r .=.�, <br /> I hereb certi that this buildin as desi ne , is in com liance Florida Statutes. .4. <br /> Y fY 9. 9 P '�,_ ,>. . �. : <br /> with the Florida Energy Code. COD�yyC;`T��� <br /> OWNER/AGENT: � BUILDIN ;OFFICIAL: <br /> DATE: �v DATE: G <br />' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br />�� certified factory-sealed in accordance with R403.2.2.1. <br />' -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 9/27/2017 6:52 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 6 <br /> I <br />