Laserfiche WebLink
; <br /> � , <br /> FORM R405-2014 <br /> FLORIDp► ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> 0417 <br /> Project Name: 2421 B sf ADS Buildar Name: Lennar Homes � <br /> street: 6659 Paden Wheel Street Permit ottice: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 469.69 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= �: <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2421.00 ft <br /> 6. Conditioned floor area above grade(ft� 2421 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ft2 <br /> 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 <br /> a. U-Factor: Dbl,U=0.54 � 140.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.58 64.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor� Dbl,U=0.56 26.67 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 4.283 ft. <br /> Area Weighted Average SHGC: 0.309 14.Hot water systems <br /> 8. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ftZ b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A � R= ft� �5.Credits Pstat <br /> � Total Proposed Modified Loads: 77.09 pASS <br /> Glass/Floor Area: 0.095 <br /> Total Baseline Loads: 77.37 <br /> I hereby certify that the plans and specifications covered by Review of.the plans and �T�.SZ'�p.. •. � <br /> this calculation are in compliance with the Florida Energy specifications covered by this t��;�. ' _T,;�0�,, �_ <br /> Code. calculation indicates compliance '�r;, '' `"'''',��.-.�c+- <br /> ?Q- . ,. '?=a*.�r .E". . <br /> /, wi t h t he F lori da Energy Co de. ' !�'rirrf�'%. �;;�="?.-;•��^�ti 0 <br /> PREPARED BY' �aVe �����'` Before construction is completed '� � �, � '� '" 0. <br /> D A T E: t his bui l ding wi l l be inspec te d for r,� �;�� ' -:- �,. <br /> compliance with Section 553.908 *, =��� = : •� <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. �" � � <br /> Y fY 9� 9 P '�?: <br /> with the Florida Energy Code. C�D`y►t6.`�� � <br /> OWNER/AGENT. BUILDING OFFICIAL: <br /> DATE. DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. � <br /> 9/27/2017 6:52 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />