Laserfiche WebLink
� � <br /> FORM R405-2014 ` <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2600B sf ADS Builder Name: LENNAR HOMES O416 <br /> street: 6647 Paden Wheel Street Permit Office: Cl��3�phyrhills <br /> City,State,Zip: ,FL, Permit Number• � <br /> Owner LENNAR HOMES Jurisdiction: 61160 � <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) � <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= �z <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10•Ceiling Types (2599.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 2599.00 ft <br /> 6. Conditioned floor area above grade(ft� 2599 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftZ <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8. <br /> a. U-Factor: Dbl,U=0.54 141.68 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.58 72.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 48.00 ftZ <br /> I SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: other(see details) 38.50 ftz a.Electric Heat Pump 42.0 HSPF:8.50 <br /> ISHGC: other(see details) <br />�i. Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2599.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftZ b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/FloorArea: 0.115 Total Proposed Modified Loads: 81.43 pASS <br />' Total Baseline Loads: 82.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ` ��T��S�Ar, •� <br />� this calculation are in compliance with the Florida Energy specifications covered by this � �,. _._���O' <br /> -�' .�_ ''. <br /> Code. calculation indicates compliance � ��+�,;,''' 4=�=:��:���.�, ., <br /> /' with the Florida Energy Code. �F+� mrr�°%-;':;�"����titi'O <br /> PREPARED BY: �aVe �����'l Before construction is completed 'r� ' '� "` '� <br /> �. 2�-.-- -. p. <br /> DATE: this building will be inspected for ��-I'� �. �: <br /> compliance with Section 553.908 * `�'�'-.� �, <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. __ <br /> Y fY 9� 9 P "� �a`�' ;F <br />' with the Florida Energy Code. � CQD�y�tE`�'�_.� <br /> OWNER/AGENT' BUILDING OFFICIAL. <br />� DATE: � � DATE: � '�� <br /> I� - Compliance requires certification by the air handler unit manufacturer that the air handle nclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house. <br /> 9/25/2017 11 43 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />