My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19367
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19367
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 9:44:42 AM
Creation date
9/24/2018 9:44:40 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19367
Building Department - Name
LENNAR HOMES LLC
Address
6647 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE�FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 26006 sf ADS Builder Name: LENNAR HOMES O416 <br /> street: 6647 Paden Wheel Street Permit oftice: City pf Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 2031.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ftz <br /> 3. Number of units,if multiple family . 1 c.N/A : <br /> R= ft <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 10.Ceiling Types (2599.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2599.00 ft2 <br /> 6. Conditioned floor area above grade(ftZ) 2599 b.N/A R= ft2 <br /> z <br /> Conditioned floor area below grade(ftZ) 0 °• R= ft <br /> 11.Ducts R ftZ <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8 <br /> a. U-Factor: Dbl,U=0.54 141.68 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.58 72.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 48.00 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: other(see details) 38.50 ftZ a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (2599.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area. 0.115 Total Proposed Modified Loads: 81.43 pASS <br /> Total Baseline Loads: 82.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �T��TAT� :. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,�'� '' "� � -p '. <br /> Code. calculation indicates compliance � r,�'� �„��1� `=_�a,��,�+ <br /> /, with the Florida Ener Code. •F+� mrr=."'�. -.,::��;:���� � <br /> PREPARED BY' J7G�I/� �GD�Y(GYG gy � ' "�,•;,' �� � <br /> Before construction is completed �'r� � .. <br /> DATE: this building will be inspected for �' �''� '- - - .�, <br /> '�,^ � - <br /> compliance with Section 553.908 * : �, <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � <br /> ' '�` -.-_. � <br /> with the Florida Energy Code. /� G'O;p'y�.��:: <br /> OWNER/AGENT: BUILDING OFFICIAL. <br /> DATE: DATE: � 0 <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RE3NET Standards, is not greater than 0.050 Qn for whole house. <br /> 9/25l2017 11 43 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.