Laserfiche WebLink
r � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2600B sf ADS Builder Name: LENNAR HOMES O416 <br /> street: 6647 Paden Wheel Street Perm�t os��e: City pf Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: <br /> Owner: LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2031.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A z <br /> R= ft <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2599.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2599.00 ftZ <br /> 6. Conditioned floor area above grade(ft2) 2599 �� b.N/A R= ft2 <br /> : <br /> Conditioned floor area below grade(ftz) 0 �• R= ft <br /> 11 Ducts R ftZ <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.8 <br /> a. U-Factor: Dbl,U=0.54 141.68 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl, U=0.58 72.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 48.00 ftz <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: other(see details) 38.50 ftz a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area Weighted Average SHGC: 0.310 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2599.0 sqft.) Insulation Area EF�0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ftZ b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ �5.Credits Pstat <br /> � <br /> Glass/Floor Area: 0.115 <br /> Total Proposed Modified Loads: 81.43 pASS <br /> Total Baseline Loads: 82.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �'Ck�E:�T�q�, -.. <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,�'� ''�_�}\�p�,'. <br /> Code. calculation indicates compliance �''��,,;''% __-';�� .�; . <br /> with the Florida Energy Code. �' ��r��r�'%%.;;::z�.�`;�"�``„ O <br /> PREPARED BY: �aVe ���'l�� Before construction is completed c`�'�d �-; ''� ` � <br /> DATE. this buildin will be ins ected for �' � <br /> 9 P t9 ��'(��- .. ` ,� <br /> compliance with Section 553.908 " * : �, <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. . ` ,�. _ <br /> �C �� _. <br /> with the Florida Energy Code. ;p�y�� - <br /> OWNER/AGENT: BUILDIN OFFICIAL: - <br /> DATE: DATE: - � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. <br /> 9/25l2017 11 43 AM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />