Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Resideritial Performance Method <br /> Project Name: Cali Elevation C /� Builder Name: DRH Express Ho es , <br /> Street: ��� l. .S����%�� C'�:�(;�i Permit Office: � c c <br /> �� �( � � �t�I ��� z�� �/� <br /> City,State,Zip: Zephyrhills, FL,3S'� _ Permit Number• �Q�6� <br /> Owner: Jurisdiction: �d <br /> Desi gn Loc a tion: FL,T a m p a � � C o u n t y:. Pa����da C iima te Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz <br /> b. Frame-Wood,Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4 Number of Bedrooms 4 _._ d.N/A R_ ftZ <br /> 7 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case. No a. Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1828 b:N/A R_ ftz <br /> Conditioned floor area below grade(ftz) 0 � c.N/A R= ftz <br /> 11 Ducts R ftz <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl, U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtuJhr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N1A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a. Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area <br /> a. Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz EF:0.950 <br /> b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftZ 15.Credits <br /> Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.55 pASS <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.�^�#i��7�,�x,fi <br /> this calculation are in compliance with the Florida Energy specifications covered by this -� =� p <br /> Code. '�.: �r=;;- <br /> calculation indicates compliance ��i�,,, �� ;_ `.� ri+ <br /> with the Florida Energy Code. F� rr,r,��..���,�;;e;�;=;;�`°`„�O <br /> '�G :a�' �„�.,_. <br /> PREPARED BY: 1.'M4 .,,�,,�... Before construction is completed w --� ' � <br /> DATE: io-ao-n this buildin will be ins ected for � ��--$'`�� ^ ,Q <br /> 9 P � _��;; �, <br /> compliance with Section 553.908 * * <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. j� } �,t <br /> with the Florida Energy Code. ,pD�.�a� <br /> OWNER/AGENZ:='�'`� G' �� BUILDING OF ICI • <br /> , DATE: o� � DATE: <br /> - Compliance requlres certification by the air handler unit manufacturer that the air handler enclosure qualifies as _ <br /> - certified factory-sealed in accordance with R403.2.2.1. , <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 10/30/2017 11:59 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />