My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19369
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19369
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2018 10:29:26 AM
Creation date
9/24/2018 10:29:22 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19369
Building Department - Name
DR HORTON INC
Address
6904 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 - <br /> FLORID�► ENERGY EFFICIE�lCY CODE FO� BUILDING CONST�UCTIO�1 <br /> Florida Department of Business and Professional Regulation - Residential Pertormance Method � <br /> Project Name: Cali Elevation C �',� ��/ Buiider Name: DRH Express Homes <br /> I Street: �Oc�Q GI Si�V��`��� ���u��(�� Permit Office: <br /> City,State,Zip: Zephyrhills,FL,3S'� . Permit Number: <br />, Owner. � � Jurisdiction: <br /> Design Location: FL,Tampa '� County:: Pasco(Florida Ciimate Zone 2) <br /> . 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. .Number of units,if muitiple family 1 c.N/A_ R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R_ ft2 <br /> ? 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case. No a.Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11. Ducts R ftz <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl, U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 - <br /> b. U-Factor: Dbi, U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br />� d. U-Factor N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br />, Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area <br /> a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge Insulation R=0:0 1828.00 ftz b. Conservation features EF:0.950 <br /> b.N/A R= ftz None <br /> c.N/A R= ft2 15.Credits <br /> Pstat <br /> Total Proposed Modified Loads: 60.55 � A �� <br /> Glass/Floor Area: 0.091 Total Baseline Loads: 61.25 ��� <br /> I hereby certify that the plans and specifications covered by Review of the�plans and � ���HE3�?, <br /> this calculation are in compliance with the Florida Energy specifications covered by this ti - .. �p <br /> Code. ' t calculation indicates compliance �k�,,�'''�t =�,;��� ";'.,� . <br /> with the Florida Ener Code. H �hr,�,,, �. :...,�tv``� C <br /> 9Y � T ���:-Y;'��:��..�::,." a <br /> PREPARED BY: �'n1�- .+�.�. Before construction is completed �� � <br /> io-�o-n t``r_.--: �Q <br /> DATE: this building will be inspected for � <br /> _��'�' <br /> compliance with Section 553.908 * �� * <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. 1� ' �,S <br /> with the Florida Energy Code. - G'pD�.�t� <br /> OWNER/AGENT:�'���1����►" r�-- BUILDING O FICIAL: <br /> DATE: . I-,-�-c,�� ;�-��� DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that�the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. - _ _ <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. - <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested.in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn#or whole house. <br /> 1 0/30/201 7 1 1:59 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 I <br />
The URL can be used to link to this page
Your browser does not support the video tag.