Laserfiche WebLink
�L�l �i����.�1� <br /> i <br /> � INSPECTIONS&FORENSIC,INC. <br />� 3868 Sun City Center Blvd. Ph.813-633-8000 <br />�� Sun City Center,Fl.33573 Fx.813-464-8026 <br /> S�'R�JC'TUI�AL �'IZAIVIING (RODF, FLODI�S, �VALLS) <br /> INSPECTION I�EI'ORT <br /> INSPECTION DATE: OS/09/2018 <br /> CLIENT/Community: D.R.H-TAMPA /Silverado <br /> LOT#(s)/ADDRESS: # 47/6 / 6779 Ezra Loft <br /> SUPERINTENDENT: Chris Tallant <br /> WEATHER: 57 clear <br /> INSPECTION CRITERIA/PROTOCOL <br /> OBSERVED&1NSPECTED PASS FAIL <br /> 1. Verify permitted ARCHITECTURAL&STRUCTURAL PLANS on-site X <br /> 2 Verify that all MECHAIVICAL,ELECTRICAL&PLUMBING SYSTEMS are X <br /> installed • <br /> 3 Verify that all WINDOWS&DOORS installed per permitted plans or product X <br /> a roval whichever is more strin ent <br /> 4. Verify that ROOF TRUSS LAYOUT is per truss shop drawings X <br /> 5 Inspect TIE-BEAM to verify that tie-beams are fully grouted to top surface with X <br /> special attention at each truss bearing location <br /> Verify that all PERMANENT ROOF TRUSS WEB BRACING typically Web"T" or <br /> 6. "Scab" is installed and is attached/nailed per truss shop drawings or continuous mid- X <br /> web 2x41ateral brace er sho drawin s <br /> Verify that LATERAL 2X4 PERMANENT LATERAL TRUSS BRACING ends at a <br /> 7. braced point either x-braced or attached to web having 2x4 stiff-back or to a gable- X <br /> end vertical <br /> Verify that WEB BRACING IS LENGTH specified on TRUSS SHOP DRAWINGS <br /> g� over the WEB but not stopped further from end by more that 6° X <br /> 9 Verify that all ROOF TRUSS 2X4 BOTTOM CHORD RAT-RiJNS AT 10'o/c X I <br /> installed <br /> 10. Verify that all specified GABLE-END BRACING or other bracing specified installed X <br /> er lans <br /> Verify that all TRUSS ANCHORS STRAPS,BUCKETS or otherwise at bearing <br /> 11. �,alls are those specified on the PLANS and fully filled with fasteners X <br />