Laserfiche WebLink
�EINTRAU� <br /> I INSPECTIONS &FORENSIC,INC. <br /> 3868 Sun City Center Blvd. Ph.813-633-8000 <br /> Sun City Center,Fl.33573 Fx.813-464-8026 <br /> Inspect accessible ROOF TRUSS GUSSET PLATES from 2nd floor to verify plates <br /> 12. are fully embedded in wood truss member and/or not excessively nailed-in to truss X <br /> members <br /> Observe accessible/visible(from floor)ROOF OR FLOOR TRUSS CONNECTOR <br /> PLATES for WANES IN PLATE CONCAT AREA.Note&require truss engineer to <br /> 1�• inspect/certify where more than 3 plates on a given truss are observed with connector X <br /> plate over waned lumber(note deficiency on floor below) <br /> Look for any obvious OUT OF PLUMB/RACKED TRUSSES,shall not be racked <br /> 14. more that the truss depth in inches divided by 50(50" deep truss not greater than X <br /> 50/50=1") <br /> 15. Look for any BROKEN ROOF TRUSS MEMBERS visible from 2nd floor,Note X <br /> location of break on floor deck below truss and re ort <br /> 16. Verify that all exterior second floor wood frame walls to masonry METAL TIE X <br /> STRAPS installed er lans <br /> 17 Verify that all WOOD STUD WALL METAL HOLD-DOWN anchorage typically at X <br /> osting or window'ambs installed er lans <br /> 18. Verify WALL STiJDS are size,grade and spacing per plans X <br /> 19. Verify STUD WALL BLOCKING per plans X <br /> 20. Verify the number of KING STUDS OR JAMB STUDS are per plans X <br /> Verify that bearing WALL STUDS ARE NOT CUT/NOTCHED more that 25%of . <br /> 21' width(7/8"max.for 2x4...1 3/8"max for 2x6) X <br /> 22 Verify that bearing WALL STUDS ARE NOT BORED OR DRILLED more than X <br /> 60%of stud width(2" for 2x4;3" for 2x6)and hole not less than 5/8 from end <br /> 2� Verify that all specified STiJD WALL UPLIFT BOLTS,nuts and washer installed X <br /> per plans <br /> 24. Verify that FLOOR TRUSS LAYOUT is per truss shop drawings X <br /> 25 Verify that floor truss STRONG-BACKS are 2x6 min.and located per shop drawings X <br /> but not greater than 10'o/c <br /> Look for any BROKEN FLOOR TRUSS MEMBERS visible from 1 st floor,Note <br /> 26' location of break on concrete floor deck below truss and report X <br /> ' At LEDGERS AND/OR SILL PLATES attached/bolted to masonry verify the type, <br /> 27' size and spacing of specified anchors in accordance with X <br /> Verify that all UNTREATED WOOD FRAMING MEMBERS ARE NOT IN <br /> 28• CONTACT WITH MASONRY OR CONCRETE separated by a durable isolation X <br /> barrier,i.e., 15#felt or alike,OR metal late <br />