Laserfiche WebLink
J ` � ' <br /> Manual S Compliance Report Job: <br /> -�- wrightsoft9 Date: Oct 10,2014 <br /> Entire House � 8,,: <br /> Progressive Air Systems, Inc _ <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> � • ' • i <br /> For: , DR Horton <br /> � Lot 1 BIk 7 Silverado Ranch, Zephyrhills, FL <br /> • • • • • <br /> Design Conditions • Z <br /> Outdoor design DB: 91.2°F Sensible gain: 21334 Btuh Entering coil DB: 76.1°F <br /> � Outdoor design WB: 77.1°F Latent gain: 2877 Btuh� Entering coil WB: 63.0°F <br /> Indoor design DB: 75.0°F Total gain: 24211 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions � <br /> Equipmenttype: SpIitASHP _ - <br /> Manufacturer: Carrier Model: CH14N6030'***A+FB4CNP030 <br /> Actual airflow: 1000 cfm � <br /> Sensible capacity: 23532 Btuh 110% of load <br /> Latent capacity: 3786 Btuh 132% of load - <br /> Total capacity: 27318 Btuh 113%of load SHR: 86% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 20312 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14N6030***#A+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25625 Btuh 126%of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm � <br /> Output capacity: 6.4 kW 108%of load Temp. rise: 20 °F <br /> Meets are all requirements of ACCA Manual S. � - <br /> .� -�} wri htsoft'` 2on-occ-so,o:s�:,s <br /> �� "f 9 Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...on\Wrightsoft Files\E�ress homesVlria 4EAB.rup Calc=MJ8 House faces: W <br />