My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19438
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19438
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:39:22 AM
Creation date
1/31/2019 9:39:21 AM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
18-19438
Building Department - Name
CITY OF ZEPHYRHILLS
Address
39317 AIR PARK RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From:UNIQCO GROUP LLG 03/13/2018 14:16 #457 P.007/008 <br /> LIMITATIONS OF USE FOR NON-HIGH VELOCITY HURRICANE ZONES <br /> Minimum Slope: 1/212 <br /> Substrate: Steel <br /> Substrate Description: Purlins or FL P.E. designed.equal. <br /> Substrate Attachment: Designed by FL P.E. per FBC.0 edition (2017). <br /> Fire Barrier: Class A fire exposure rating in accordance with FBC <br /> Section 1505.1 with UL 790. - <br /> Insulation: (Optional)Vinyl or reflective foil faced fiberglass <br /> batten insulations that have a flame spread rating of <br /> no more than 26 and a smoke development rating of <br /> not more than 450. <br /> Minimum Substrate Thickness: 16-ga purlins or FL P.E.designed equal per FBC 6th <br /> Edition (2017). <br /> Documentation Supporting the Compliance Statement <br /> The product has been tested in accordance with- <br /> • ASTM E 1592-01: Test Report 07-0045T-07 A, B, E, F dated 4-03-07 by Force <br /> Engineering & Testing, Inc. located in Humble, Texas. The ASTM E 1592-01 test <br /> standard is equivalent to the ASTM E 1592-05(2012)test standard. <br /> • UL 580 Testing through UL construction#542 located in Northbrook, IL 60062. <br /> • FM 4471 "Foot Traffic"for roof slopes 2:12 or less-Test Report 07-0172T-17 <br /> dated 09-21-17 by Force Engineering &Testing, Inc. located in Humble, TX 77338. <br /> The FM 4471-92 test standard is equivalent to the FM 4471-10 test standard. <br /> Maximum Uplift Pressure: Contact Manufacturer for additional uplift pressures <br /> and panel spans. <br /> Application: Install PBR Panel per the manufacturers approved <br /> detail. <br /> Test Design Pressures: <br /> 29 ga. PBR-66 psf @ 4 ft o.c.spans <br /> 26 ga. PBR-80 psf @ 4 ft o.c.spans of P40a <br /> r=k <br /> JL 24 ga. PBR-90 psf @ 4 ft o.c.spans ✓ <br /> 22 ga. PBR-142.6 psf @ 4 ft o.c.spans <br /> N <br /> N o.4 4 9 2 3 <br /> STATE OF <br /> R�- <br /> Oft,,,, <br /> 1410"s i <br /> 6EP 2 2 20W <br />
The URL can be used to link to this page
Your browser does not support the video tag.