Laserfiche WebLink
From:UNIOCO GROUP LLC 03/13/2018 14:16 #457 P.0061008 <br /> 1607.4.3 Material standards. Metal-sheet roof covering systems that incorporate <br /> supporting structural members shall be designed in accordance with Chapter 22. Metal- <br /> sheet roof coverings installed over structural decking shall comply with Table 1507.4.3(2). <br /> Table 1507.4.3(2)Metal Roof Covent s <br /> -Roof Covering Pe Minimum Ap lication Rate <br /> 65%Aluminum-Zinc Alloy Coated Steel ASTM A 792 AZ 50 <br /> 50/a Aluminum Alloy Coated Steel ASTM A 875 GF60 <br /> Galvanized Steel ASTM A653C,-90 <br /> Pre painted Steel ASTM A 765 <br /> 1607.4.4 Attachment Metal roof panels shall be secured to the supports in accordance <br /> With the manufacturers fasteners. In absence of manufacturer recommendations, the <br /> following fasteners shall be used. <br /> 1. Galvanized fasteners shall be used for steel roofs. <br /> 2. Copper, brass, bronze, copper alloy or 300 series stainless-steel fasteners shall be <br /> used for copper roofs. <br /> 3.Aluminum-zinc,coated fasteners are acceptable for aluminum zinc coated roofs. <br /> 4. Stainless-steel fasteners are acceptable for all types of metal root. <br /> CHAPTER 22 <br /> STEEL <br /> SECTION 2210 <br /> COLD-FORMED STEEL CONSTRUCTION <br /> 2210.1 Regular cold-formed steel. The design of cold-formed,carbon and low-alloy <br /> steel structural members shall,be in accordance AISI S100. <br /> OWL <br /> ton <br /> % <br /> • <br /> No.44023 <br /> STATE 0 <br /> ONKIAL <br /> -SEP 2 2 2011 <br />