Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project'Name: 4259AB sf ADS Builder Name: Lennar Homes 0418 <br /> Street: 6671 Paden Wheel Street Permit office: City of Zephyrhills <br /> City,State,Zip: FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ftz <br /> 4. Number of Bedrooms 6 d.N/A R= ftz <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2347.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 4259 b.Knee Wall(Vented) R=30.0 152.00 ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 <br /> a. U-Factor: Dbl,U=0.54 298.01 ftz b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor. Dbl,U=0.56 98.69 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.58 72.00 ftz b.Central Unit 30.0 SEER:15.00 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: other(see details) 50.00 ftz a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4.720 ft. <br /> Area Weighted Average SHGC: 0.305 14.Hot water systems <br /> 8. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Floor Over Other Space R=0.0 2060.00 ftz b. Conservation features EF:0.950 <br /> b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ftz None <br /> c.other(see details) R= 287.00 ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.122 <br /> Total Proposed Modified Loads: 120.59 PASS <br /> Total Baseline Loads: 122.51 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 4 Tk1E:ST�j?, <br /> this calculation are in compliance with the Florida Energy specifications covered by this = <br /> Code. calculation indicates compliance <br /> �ave (��lGl'l with the Florida EnergyCode. <br /> PREPARED BY: Before construction is completed <br /> DATE: this buildingwill be inspected for <br /> P <br /> compliance with Section 553.908 *, <br /> hereby certify that this building,as designed, is in compliance Florida Statutes. ; <br /> with the Florida Energy Code. �'Op �� <br /> OWNER/AGENT: BUILDING - FFICIAL: <br /> DATE: DATE: 0i <br /> I <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house. <br /> 7/27/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />