Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> 0418 <br /> Project Name: 4259AB sf ADS BuilderName: Lennar Homes <br /> Street: 6671 Paden Wheel Street Pemit office: City of Zephyrhilis <br /> City,State,Zip: FL, Permit Number: <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ft2 <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ft2 <br /> 4. Number of Bedrooms 6 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2347.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 <br /> a. U-Factor: Dbl,U=0.54 298.01 ft2 b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 98.69 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.58 72.00 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: other(see details) 50.00 ft2 a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4.720 ft. j <br /> Area Weighted Average SHGC: 0.305 14.Hot water systems <br /> 8. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Floor Over Other Space R=0.0 2060.00 ft2 b. Conservation features EF:0.950 <br /> b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft2 None <br /> c.other(see details) R= 287.00 ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.122 Total Proposed Modified Loads: 120.59 PASS <br /> Total Baseline Loads: 122.51 <br /> 01 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 'C <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> /Ii•• %gip� <br /> � �J�G� with the Florida Energy Code. F+° rim :r. • , , <br /> Dave <br /> PREPARED BY: Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .� <br /> with the Florida Energy Code. COrjv <br /> OWNER/AGENT: BUILDING OF ICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in'accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. <br /> 7/27/2017 2:42 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />