Laserfiche WebLink
• Job: 4259AB sf ADS <br /> Project Summary Date: 9/2712017 <br /> upper floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> a <br /> For: Lennar Homes <br /> Notes: <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17701 Btuh Structure 19801 Btuh <br /> Ducts 2956 Btuh Ducts 3351 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower <br /> e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 20657 Btuh Use manufacturer's data y <br /> Ratelswing multiplier 1.00 <br /> Infiltration Equipment sensible load 23152 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2388 Btuh <br /> Ducts 601 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating coolingg (none) <br /> Area(W) 2347 2347 Equipment latent load 2989 Btuh <br /> Volume(ft3) 18778 18778 <br /> Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26141 Btuh j <br /> Equiv.AVF (cfm) 82 43 Req. total capacity at 0.85 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-030-230-21 Cond 14HPX-030-230-21 <br /> AHRI ref 10258600 Coil CBA27UHE-030-230*++TDR <br /> AHRI ref 10258600 <br /> Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER <br /> Heating input Sensible cooling 25500 Btuh <br /> Heating output 26400 Btuh @ 470F Latent cooling 4500 Btuh <br /> Temperature rise 24 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.048 cfm/Btuh Air flow factor 0.043 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point=25 OF <br /> Backup: <br /> Input= 7 kW, Output=22917 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> Wrlg htso t® 2017-Sep-27 06:59:52 <br /> ACC "r Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...A27UHE AH's\4259AB sf ADS template 2.5-2ton.rup Calc=MJ8 Front Door faces:SE <br />