Laserfiche WebLink
Manual S Compliance Report Job: 4259AB sf ADS <br /> Date: 912712017 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 19850 Btuh Entering coil DB: 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 2394 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 22244 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 108% of load <br /> Latent capacity: 3780 Btuh 158% of load <br /> Total capacity: 25200 Btuh 113% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 24996 Btuh Entering coil DB: 69.6'F <br /> Indoor design DB: 70.0*F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 87% of load Capacity balance: 35 °F <br /> Supplemental heat required: 3196 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 6.7 kW 92% of load Temp. rise: 50 'F <br /> Meets are all requirements of ACCA Manual S. <br /> wri htsoft, 2017-Sep-27 06:59:52 <br /> 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 <br /> 14CC�', ...A27UHE AH's14259AB sf ADS template 2.5-2ton.rup Calc=MJ8 Front Door faces:SE <br />