Laserfiche WebLink
Project Summary Job: 2575B1 sf ADS <br /> J � Date: 211/2018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Notes: <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 14883 Btuh Structure 9705 Btuh <br /> Ducts 1400 Btuh Ducts 1655 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (gone) <br /> 0 Btuh Blower e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 16284 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 11360 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 942 Btuh <br /> Ducts 294 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1093 1093 Equipment latent load 1237 Btuh <br /> Volume(ft') 9654 9654 <br /> Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12596 Btuh <br /> Equiv.AVF(cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-018-230-21 Cond 14HPX-018-230-21 <br /> AHRI ref 10258596 Coil CBA27UHE-018-230"++TDR <br /> AHRI ref 10258596 <br /> Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER <br /> Heating input Sensible cooling 16915 Btuh <br /> Heating output 17100 Btuh @ 47°F Latent cooling 2985 Btuh <br /> Temperature rise 26 °F Total cooling 19900 Btuh <br /> Actual air flow 600 cfm Actual air flow 600 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.90 <br /> Capacity balance point= 31 °F <br /> Backup: <br /> Input=4 kW, Output= 15295 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> WI.1g htsoft" 2018-Feb-01 08:38:30 <br /> ACCA Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...A27UHE AH's1257513 sf ADS template 1.5.2 ton.rup Calc=MJ8 Front Door faces: W <br />