Project Summary Job: 2575B1 sf ADS <br /> J •7 Date: 21112018 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Notes: <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 10978 Btuh Structure 16313 Btuh <br /> Ducts 1846 Btuh Ducts 2137 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12825 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 18450 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 3162 Btuh <br /> Ducts 379 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft') 1489 1489 Equipment latent load 3541 Btuh <br /> Volume(ft') 11912 11912 <br /> Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21991 Btuh <br /> Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024-230-21 Cond 14HPX-024-230-21 <br /> AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR <br /> AHRI ref 10258598 <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.062 cfm/Btuh Air flow factor 0.043 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.84 <br /> Capacity balance point= 17°F <br /> Backup: <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> I <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> C Wrl f'1'tsoftm 2018-Feb-0108:36:30 <br /> C g Right-Sufte®Universal 2017 17.0.23 RSU05714 Page 2 <br /> �C;� ...A27UHE AH'st2575B sf ADS template 1.5-2 ton.rup Calc=MJS Front Door faces: W <br />