My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19510
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19510
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:17:29 AM
Creation date
1/31/2019 10:17:27 AM
Metadata
Fields
Template:
Building Department
Company Name
SIVLEARDO
Building Department - Doc Type
Permit
Permit #
18-19510
Building Department - Name
LENNAR HOMES LLC
Address
6594 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 2575B1 sf ADS <br /> p p Date: 211/2018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 12596 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASH <br /> Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 135% of load <br /> Latent capacity: 2700 Btuh 218% of load <br /> Total capacity: 18000 Btuh 143% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 16284 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR <br /> Actual airflow: 600 cfm <br /> Output capacity: 17500 Btuh 107% of load Capacity balance: 31 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 4.5 kW 94% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. <br /> wri htsoftm 2018-Fetr0108:38:30 <br /> 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 <br /> 14CC'A ...A27UHE AH's12575B sf ADS template 1.5-2 ton.rup Calc=MJ8 Front Door faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.