Laserfiche WebLink
Page 3 of 3 <br /> 4904.6 Wood-edge Steel Side-Hinged Door Units 6'-8"Glazed I/S and O/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.03.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:No 12/31/2020 <br /> Design Pressure:+50.51-50.5 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R8 II FL0130.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By:National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 6'-8"max nominal size.When large missile impact FL4904 R8 AE 514008A.pdf <br /> resistance is required,hurricane protective system is required.See DWG- Created by Independent Third Party:Yes <br /> MA-FL0130-05 for details. <br /> 4904.7 Wood-edge Steel Side-Hinged Door Units 8'-0"Glazed I/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C_CAC NI006110.04;.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:No 12/31/2020 <br /> Design Pressure:+40.0/45.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R8 II FL0131.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By:National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x 8'-0"max nominal size.When large missile impact FL4904 R8 AE 514007A.pdf <br /> resistance is required,hurricane protective system is required.See DWG- Created by Independent Third Party:Yes <br /> MA-FL0131-05 for details. <br /> 4904.8 Wood-edge Steel Side-Hinged Door Units 8'-0"Glazed O/S Door w/or w/o Sidelites <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ:Yes FL4904 R8 C CAC NI006110.04.pdf <br /> Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date <br /> Impact Resistant:No 12/31/2020 <br /> Design Pressure:+45.0/40.0 Installation Instructions <br /> Other:Evaluated for use in locations adhering to the Florida Building FL4904 R8 II FL0131.pdf <br /> Code including the High Velocity Hurricane Zone,and where pressure Verified By:National Accreditation&Management Institute <br /> requirements as determined by ASCE 7,Minimum Design Loads for Created by Independent Third Party: <br /> Buildings and Other Structures,does not exceed the design pressures Evaluation Reports <br /> listed. 12'-0"x T-0"max nominal size.When large missile impact FL4904 R8 AE 5.14007A.pdf <br /> resistance is required,hurricane protective system is required.See DWG- Created by Independent Third Party:Yes <br /> MA-FL0131-05 for details. <br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgteluIwHNbbISei... 3/7/2018 <br />