My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19543
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19543
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:40:55 AM
Creation date
1/31/2019 10:40:53 AM
Metadata
Fields
Template:
Building Department
Permit #
18-19543
Building Department - Name
SABRA HEALTH CARE HOLDINGS III
Address
37411 EILAND BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16. For adhered membrane systems,side laps shall be minimum 2-inch wide sealed with min.1.5-Inch heat weld.Unless otherwise noted,membrane adhesive application rates are as follows: <br /> Membrane Adhesive Method Rate <br /> Mule-Hide TPO-c Mule-Hide TPO-c Bonding Adhesive(TPO-c BA) Contact(both sides) 60 ft2/gal <br /> Mule-Hide TPO-c Aqua Base 120 BA Contact(both sides) 120 ft2/gal <br /> Mule Hide TPO-c Fleece Back Aqua Base 120 BA Wet lay(substrate) 120 ft2/gal <br /> Mule-Hide TPO-c Fleece Back Mule-Hide Helix°Low-Rise Adhesive(HELIX) Wet lay(substrate) FULL=continuous ribbdhs,maximum 4-inch o.c, <br /> 17. For membrane systems attached using TPO 10-inch Pressure-Sensitive RUSS,the underside of the membrane which comes In contact with the tape shall be primed with HP-250 Primer. The membrane shall be <br /> secured by placing the primed portion onto the tape portion of the TPO 10-inch Pressure-Sensitive RUSS and roll with a steel hand roller to ensure contact <br /> 18. For bonded membrane systems,unless otherwise noted,reference to"Mule-Hide TPO-e membrane below also includes"Mule-Hide TPO-c EXTRA". <br /> 19. Vapor barrier options for use over structural concrete deck followed by adhesive-applied Insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those In <br /> Table 3A applies. <br /> VAPOR BARRIER OPTIONS,STRUCTURAL CONCRETE DECK;FOLLOWED BY ADHESRIE-APPLIED INSULATION PER TABLE 3A: <br /> Option!# Primer Type <br /> Vapor Barrier Application Insulation Adhesive MDP(psf) <br /> VB-1. Carlisle CAV-GRIP Primer FS-Air&Vapor Barrier or Carlisle VapAirSeal 72STR Self-adhering HELIX(RIBBON,12-inch o.c.) -97.5 <br /> VB-2. ASTM D41 Carlisle SureMB 90TG Base or SureMB 120 TG Poly Base Torch-applied HELIX(RIBBON,12-inch O.c.) -97.5 <br /> VB-3. ASTM D41 Carlisle SureMB 90 Base or SureMB 120 Poly Base Hot-asphalt HELIX(RIBBON,12-inch o.c.) -97.5 <br /> 20. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. <br /> Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06,09-R4 for FL32772-R4 <br /> Certificate of Authorization#9503 FBC NON-HVHZ EVALUATION;Mule-Hide TPO-c Single Ply Roof Systems Revision 4:04/03/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide Products Co.,Inc.;(608)365-3111 Appendix 1,Page 3 of 26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.