My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19543
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19543
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 10:40:55 AM
Creation date
1/31/2019 10:40:53 AM
Metadata
Fields
Template:
Building Department
Permit #
18-19543
Building Department - Name
SABRA HEALTH CARE HOLDINGS III
Address
37411 EILAND BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE ID: WOOD DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE E-1: NON-INSULATED,MECHANICALLY ATTACHED ROOF COVER <br /> Thermal Barrier Roof Cover MOP <br /> System Roof Deck Fastener Lap Width Lap Spacing Seam Weld (pso <br /> No, Type Attach Membrane Fasteners Spacing(inch) (inch) (inch) (inch) <br /> Min.19/32-inch thick Mule-Htde FR Beck Panel Aor C or (Optional)Any Mule-Hide EHD <br /> Barrier Technology Corp"Blazeguard Aor C"at max.24-inch Mule-Hide Fasteners and 2.4 12 5 48 1.5 30.0 <br /> W-6 spans attached using No.8 x 2'!,-Inch long course thread approved Loose-laid TPO-c <br /> thermal barrier Seam Plates <br /> screws spaced 6"o.c. <br /> Min.19/32-inch thick Mule-Hide FR Deck Panel A or C or (Optional)Any Mule- Mule-Hide EHD <br /> W-7 <br /> Barrier Technology Corp"Blazeguard A or C"at max,24-inch approved Loose-laid TPO-cHide Fasteners and 2.4 6 5 72 1.5 -52.5 <br /> spans attached using No.8 x 2%-inch long course thread PO-c <br /> thermal barrier Seam Plates <br /> screws spaced 6"o.c. <br /> MIn.19/32-inch thick Mule-Hide FR Deck Panel A or C or (Optional}Any Mule-tilde EHD <br /> Barrier Technology Corp"Blazeguard A or C"at max 24 inch approved Loose-taid Mule-Hide Fasteners and 2.4 6 5 48 2.5 -75.0 <br /> W� sans attached usin No,8 x 2Y:-inch long course thread TPO c <br /> P g thermal barrier Seam Plates <br /> screws spaced 6"o.c. <br /> (optional)Any TFasteners <br /> Hide EHD 48(over <br /> Min.19/32-inch plywood at max.24 inch spans attached Mu#e-Hide <br /> W� using 8d ring shank Halls spaced 6-inch o.c. approved Loose-laid TPO_c and 2.4 6 5.5 structural 1.5 -75.0 <br /> thermal barrier Plates members) <br /> TABLE IE:WOOD DECKS-NEW CONSTRUCTION,REIROOF(TEAR-OFF)OR RECOVER <br /> SYSTEM TYPE E-2:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER <br /> System Thermal Barrier Base Sheet Roof Cover MOP <br /> No. Deck(Note 1) TYpe Attach Base Sheet Fasteners Attach Membrane Adhesive (Psi) <br /> Min.19/32-inch plywood at (Optional)Any Atlas Summit Mule-Hide Drill Point 124nch o.c.at the 4-#nch laps and 12-inch Mule-Hide SA Self- <br /> W-10 max.24-Inch spans;1110 x 2- approved Loose-laid Synthetic Fastener and Mule-Hide o.c.at three,equally spaced rows in the TPO adhered -120.0 <br /> inch wood screws,6-Inch o.c. thermal barrier Underiayment 2"Seam Plate center of the sheet. <br /> TABLE IF:WOOD DECKS—NEW CONSTRUCTION <br /> SYSTEM TYPE F.NON-INSULATED,BONDED ROOF COVER <br /> Roof Cover(Note 16) MOP <br /> System Roof peck <br /> No. Membrane Application (Pso <br /> W 11 Min.15/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C`at Mule-Hide TPO-c Aqua Base 120 BA -4S.0 <br /> max.24-Inch spans attached using No.8 x 2%-Inch long course thread screws spaced 6"o.c. <br /> W-12 Mtn.19/32-inch thick Mule-Hide FR Deck Panel A or C or Barrier Technology Corp"Blazeguard A or C'at Mule-Hide TPO-c Aqua Base 120 BA -52.5 <br /> max.24-inch spans attached using No.8 x 2%-inch long course thread screws spaced 6"o.c. <br /> Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R4 for FL12772-R4 <br /> Certificate of Authorization#9503 FBC NON-HV13Z EVALUATION;Mute-Hide TPB-c S s Revision 4:04/03/2017 <br /> Single Ply Roof System <br /> Prepared by:Robert Nieminen,PE-59166 Mule-Hide Products Co.,Inc;(608)365-3113 Appendix 1,Page S of 26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.