<br /> TABLE 2B: STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER
<br /> SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
<br /> System Deck Top Insulation layer MDP
<br /> Base Insulation Layer Roof Cover(Note 16)
<br /> No. (Note 1) Type Fasteners Attach (Psf)
<br /> MurE-HIDE TPO-C APPUCA,M0N5:
<br /> SC-16 Min.22 ga.,type B,Grade 33 steel Min.IS"thick,one or more layers, Min 7/1V APA or TECO rated OSB Trufast SIP LD 1 per 3.2 ft' Mule-Hide TPO-c/TPO-c BA or Aqua -37.5'
<br /> any combination,loose laid Fasteners Base 120 BA
<br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1-Inch Poly ISO 2,ACFoam II Mule-Hide TPO-c/TPO-c BA or Aqua
<br /> SC-17 min.2,500 psi structural concrete combination,loose laid or ENRGY 3 Note 2 1 per 1.6 ft� Base 120 BA -37.5
<br /> Min.22 ga.,type B,Grade 33 steel or Min.1.5-Inch thick,one or more z e
<br /> SC-18 min.2,500 psi structural concrete layers,any combination,loose laid Min.0.5 inch H-Shield HD Note 2 1 per 2.67 ft Mule Hide TPO-c/TPO-c BA 37.5
<br /> SC-19 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0,25-inch SECUROCK Gypsum- Note 2 1 per 2.67 ft' Mule-Hide TPO-c/TPO-c BA or Aqua 37 5'
<br /> min:2,50D psi structural concrete layers,any combination,loose laid Fiber Roof Board Base 120 BA
<br /> SC-20 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.50-inch SECUROCK Gypsum- Note 2 1 per 3.2 ft' Mule-Hide TPO-c/TPO-c BA or Aqua -45.0•
<br /> min.2,50D psi structural concrete layers,any combination,loose laid Fiber Roof Board Base 120 BA
<br /> SC-21 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.625-inch SECUROCK Note 2 1 per 4.0 ft' Mule-Hide TPO-c/TPO-c BA or Aqua -45.0"
<br /> min.2,500 psi structural concrete layers,any combination,loose laid Gypsum-Fiber Roof Board Base 120 BA
<br /> SC-22 Min.22 ga-,type B,Grade 33 steel Min.1.5"thick,one or more layers, Min 7/16"APA or TECO rated OSB Trufast SIP LD 1 per 2.67 W Mule-Hide TPO-c/TPO-c BA or Aqua -45.0'
<br /> any combination,loose laid Fasteners Base 120 BA
<br /> SC-23 Min.22 ga.,type B,Grade 33 steel or One or more layers,any combination, Min 7116"APA or TECO rated OSB Note 2 1 per 3.6 ft' Mule-Hide TPO-c/TPO-c BA or Aqua -45.0'
<br /> min.2,500 psi structural concrete loose laid Base 120 BA
<br /> SC-24 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1-inch Poly ISO 1,H-Shleld,H- Note 2 1 per 1.6 ft' Mule-Hide TPO-c/TPO-c BA or Aqua -45.0'
<br /> min.2,500 psi structural concrete combination,loose laid Shield CG Base 120 BA
<br /> SC-25 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any 2 Min.1.S-inch ACFoam II,Poly ISO,H-Shield,Poly ISO 1,H-Shield Note 2 1 per 2.0 ft' Mule-Hide TPO-c/TPO-c BA or Aqua _45.0'
<br /> min.2,500 psi structural concrete combination,loose laid 2, EN 3 Base 120 BA
<br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.2.0-inch ACFoam 11,Poly ISO Mule-Hide TPO-c/TPO-c BA or Aqua
<br /> SC-26 min.2,500 psi structural concrete combination,loose laid 2,H-Shleld,Poly ISO 1,H-Shield Note 2 1 per 4.0 ft Base 120 BA -45.0
<br /> CG,ENRGY 3
<br /> Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more t a
<br /> SC-27 min.2,500 psi structural concrete layers,any combination,loose laid Min.0.5-inch H-Shield HD Note 2 1 per 2.0 ft Mule-Hide TPO-c/TPO c BA 45.0
<br /> SC-28 Min.22 ga.,type B,Grade 33 steel or Min.1.5"thiclk,one or more layers, Min 7/16"APA or TECO rated OSB Note 2 1 per 1.9 ft' Mule-Hide TPO-c/Aqua Base 120 -52.5
<br /> min.2,500 psi structural concrete any combination,loose laid BA
<br /> SC 29 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.5-Inch Dens Deck Prime Note 2 1 per 1.6 W Mule-Hide TPO-c/TPO-c BA -60.0
<br /> min.2,500 psi structural concrete layers,any combination,loose laid
<br /> Min.22 ga.,type B,Grade 33 steel or Min.1.5"thick,one or more layers, r
<br /> SC-30 min.2,500 psi structural concrete any combination,loose laid Min 7/16"APA or TECO rated OSB Note 2 1 per 1.9 ft Mule-HideTPO-c/TPO c BA -75.0
<br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min 2.0-inch ACFoam II,Poly ISO 1,
<br /> SC-31 min.2,500 psi structural concrete combination,loose laid Poly ISO 2,H-Shield,H-Shield CG, Note 2 1 per 1.6 ft' Mule-Hide TPO-c/TPO-c BA -75.0
<br /> ENRGY3
<br /> Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report NI15060.06.09-R4 for FL12772-R4
<br /> Certificate of Authorization 49503 FBC NON-HVFIZ EVALUATION;Mule-Hide TPO-c Single Ply Roof Systems Revision 4:04/03/2017
<br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide Products Co.,Inc.;(608)365-3111 Appendix 1,Page 8 of 26