TABLE 2B: STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF{Tear-Off}or RECOVER
<br /> SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
<br /> System Deck Top insulation Layer MDP
<br /> No. (Note 1) Base Insulation Layer Type Fasteners Attach Roof Cover{Note 16} (PsQ
<br /> SC-32 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.5-inch SECUROCKGypsum- Note 2 1 per 1.6 ft° Mule-Hide TPO-c/TPO-c BA -82.5
<br /> min.2,500 psi structural concrete layers,any combination,loose laid Fiber Roof Board
<br /> SC-33 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 7/16-inch APA orTECO rated Note 2 1 per 1 ftz Mule-Hide TPO-c/TPO-c BA -97.5
<br /> min.2,500 psi structural concrete layers,any combination,loose laid OSB
<br /> Min.20 ga.,type 8,Grade 33 steel or (Optional)Min.1.S-Inch thick,one or Min.0.625-inch SECUROCK SC-34 min.2,500 psi structural concrete more layers,any combination,loose Gypsum-Fiber Roof Board Note 2 1 per 1.33 ftz Mule-Hide TPO-c/TPO-c BA -112.5
<br /> laid
<br /> SC-35 Min.i8 ga,type B,Grade 33 steel or Min.2-inch thick,one or more layers, Min.0.5-inch SECUROCK Gypsum- Note 2 1 per 1.33 ft' Mule-Hide TPO-c/TPO-c BA -1125
<br /> min.2,500 psi structural concrete any combination,loose laid Fiber Roof Board
<br /> SC-36 Min.22 ga,type B,Grade 33 steel or (Optional)one or more layers,any Min 2-inch H-Shield CG Note 2 1 per 1 ft' Mule-Hide TPO-c/TPO-c BA -120.0
<br /> min.2,500 psi structural concrete combination,loose laid
<br /> MULE-HIDE SA-TPO AepurAnaws:
<br /> Min.22 ga,type B,Grade 33 steel or (Optional for Recover)Min,1.5-inch r
<br /> SC-37 min.2,500 psi structural concrete thick,one or more layers,any Min.2-inch insulfoam SP Note 2 1 per 2.7 ft Mule-Hide SA TPO,self-adhered -30.0
<br /> combination,loose laid
<br /> Min.22 ga.,type B,Grade 33 steel or (Optional for Recover)Min.1.5-inch r «
<br /> SC-38 min,2,500 psi structural concrete thick,one or more layers,any Min.2-inch Insulfoam SP Note 2 1 per 2.0 ft Mule-Hide SA-TPO,self-adhered -45.0
<br /> combination,loose laid
<br /> {Optional for Recover}Min.15-Inch Min.0.254nch Dens Deck Prime or
<br /> Min.22 ga.,type B,Grade 33 sleet or SECUROCK Gypsum-Fiber Roof
<br /> SC-39 min.2,500 psi structural concrete thick,one or more layers,any Board or min 7/15-inch APA or Note 2 1 per 2.0 fti Mule-Hide SA Tpq,self-adhered 45,0*
<br /> combination,loose laid TECO rated OSB
<br /> Min.22 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.2.5-inch Poly 1501,H-Shield,
<br /> SC-40 min.2,500 psi structural concrete more layers,any combination,loose Polyiso HP-H,SecurShield,H-Shield Note 2 1 per 2.0 W Mule-Hide SA TPO,self-adhered -45.4
<br /> laid CG
<br /> Min.22 ga.,type B,Grade 33 steel or (Optional)Min.1.5-Inch thick,one or Min.2.0-Inch Poly ISO 1,H-Shield,
<br /> SC-41 min.2,500 psi structural concrete more layers,any combination,loose Polyiso HP-H,SecurShleld,H-Shield Note 2 1 per 1.6 ftz Mule-Hide SA-TPO,self-adhered -60.0
<br /> laid CG
<br /> Exterior Research and Design,I.I.C.d/b/a Trinity ERD Evaluation Report M15060.06.09-R4 for F1.12772-114
<br /> Certificate of Authorization#9S03 FBC NON-HVHZ EVALUATION;Mule-Hide TPO-t Single Ply Roof Systems Revision 4:04/0312017
<br /> Prepared by: Robert Nleminen,PE-59166 Mulo-Hide Products Co.,Inc.,(608)365-3111 Appendix 1,Page 9 of 26
<br />
|