Laserfiche WebLink
Manual S Compliance Report Job: R0318107 <br /> - wrightsoft- p P Date: 0310812018 <br /> Entire House By: MKC <br /> Teri Butterfield <br /> 37516 Cook Ave,Dade City,FL <br /> Project • • <br /> For. Butterfield Investments,Inc. <br /> 5130 20th St,Zephyrhills,FL 33542 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 20273 Btuh Entering coil DB: 79.1 OF <br /> Outdoor design WB: - 77.2°F Latent gain: 3928 Btuh Entering coil WB: 64.4°F <br /> Indoor design DB: 75.0°F Total gain: 24201 Btuh <br /> Indoor RH: 50% Estimated airflow: 927 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer. Goodman Mfg.or Eqv Model: GSZ14030+AVPTC37 <br /> Actual airflow: 927 cfm <br /> Sensible capacity: , 20294 Btuh 100%of load <br /> Latent capacity: 7506 Btuh 191%of load <br /> Total capacity. 27800_ Btuh 115%of load SHR: 73% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 19555 Btuh Entering coil DB: 69.1°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SplitASHP <br /> Manufacturer. Goodman Mfg.or Eqv Model: GSZ14030+AVPTC37 <br /> Actual airflow: 927 cIrn <br /> Output capacity: 28000 Btuh 143%of load Capacity balance: 35 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer. Model: <br /> Actual airflow. 927 c6n <br /> Output capacity: 8.0 kW 140%of load Temp.rise: 27 OF <br /> Meets all requirements ofACCA Manual S. <br /> wrightsoft- 2018-Mar-0915 0223 <br /> Rigtt SUte@ Uriversal 201818.0.10 RSU20773 Page 1 <br /> ACCA ...aWorkHe1R0318107-5130 20thStR0318107.np Calc=MJ8 Frort Door faces:W <br /> f <br />