Laserfiche WebLink
wrightsoW Project Summary Job: R0318107 <br /> Date, 0310812018 <br /> Entire House By: MKC <br /> Teri Butterfield <br /> 37516 Cookke,Dade City,FL <br /> Project Information <br /> For. Butterfield Investments Inc, <br /> 5130 20th St,Zephyrhills, 33542 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> Desicin Information <br /> Weather. Tampa InflAR FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 27 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 grfib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 16014 Btuh Structure 13397 Btuh <br /> Ducts 3541 Btuh Ducts 5169 Btuh <br /> Central vent(0 d1m) 0 Btuh Central vent(0 cfirn) 0 Btuh <br /> (gone) (none) <br /> Humidification 0 Btuh Blower 1707 Btuh <br /> Piping 0 Btuh <br /> Equipment load 19555 Btuh Use manufacturers data y <br /> RatelsWqn It ' 1.00 1 Equ,pmenj mu p Jer <br /> Infiltration sensible load 20273 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2406 Btuh <br /> Ducts Btuh <br /> Central vent(0 cfim) 1522 0 Btuh <br /> He ti Coo (none) <br /> Area(ftZ) IM - ft Equipment latent load 3928 Btuh <br /> Molurne(fl?) 13152 13162 <br /> A r changesthour 0.38 — 0.20 Equipment Total Load(Sen+Lat) 24201 Btuh <br /> Equiv.A\/F(cfirn) 83 44 Rdq-total capacity at 0.73 SHR 2.3 ton <br /> Heating Equipment Summary I Cooling Equipment Summary <br /> Make Goodman Mfg.or Eqv Make Goodman Mfg.or Eqv <br /> Trade Split HP Trade Split HP <br /> Model GSZ14030 Cond GSZ14030 <br /> AHRI ref 8996184 Coil AVPrTC37 <br /> - AHRI ref 8996184 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER 15 SEER <br /> Heating input Sensible cooling 20294 Btuh <br /> Heating output 28000 Btuh @ 47-F Latent cooling 7506, Btuh <br /> Temperature rise 27 OF Total cooling 27800 Btuh <br /> Actual airflow 927 cirri Actual airflow 927 ckn <br /> Airflowfactor 0.047 dm/Btuh Airflowfactor 0.050 cfim/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.84 <br /> Capacity balance point=35 OF <br /> Backup: Aux Heat <br /> Input=8kW, Output=27297 Btuh,100 AFUE <br /> Calculations approved byACCAto meet all requirements of Manual J 8th Ed. <br /> -rk Pjgtt-Sdte@Udwrw1 2018 18.0.10 RSU20773 2018-Mar-09 15':02:23 <br /> Aft -513020thSW0318107np Ca1c=MJ8 FrortWorlaces;W Page I <br /> aworkReR0318107 <br />