My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19600
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19600
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 9:01:16 AM
Creation date
2/7/2019 9:01:14 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19600
Building Department - Name
LENNAR HOMES LLC
Address
6652 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Single. Family .Dwelling <br /> Plan-Review Cominents <br /> 1 F.F.E. shall'be a minimum=of 8".above,the road.elevation and an engirieered.site plan. <br /> '2. Lots shall be graded.to comply with R401.3 of the F.B;C: <br /> 3. Compaction test required.if 24"'or mor&of fill dirt is brought in.at any one place: <br /> 4: 'Tie in. .urvey required before pounng concrete. <br /> 5. Driveways require a.R.O:W.use permit: All 4 sides of driveway thru the sidewalk shall_l aye <br /> expansion matenaL <br /> 6. All setbacks-shall be met... <br /> .7. All.property:mar e,rs shall be.uncovered"and marked at tim_ a"of first 'inspection: <br /> 8: :All A.D.A. requirements.shall be met.:'. <br /> 9.. No electric,plumbing,.mechanical,orfraining shall be covered without an.inspection"and <br /> approval first. . .. <br /> 10. All. Garages shall:comply.with:section R302.6.of the:F.B.C. (Fire Separation)'..' <br /> -.11. Appliances shall not:be installed in."a location where subject to mechanical darriage uriles5. <br /> protected.by approved barriers: M303 4 of the F.B.0 <br /> T2. Water. shall_comply with section`P607.3 of the"F.B.C: <br /> 13. Foundation supports for."A/C.units shall be raised at least 3'.' above finish grade., M1308.1 <br /> 14. Return-air in all._bedroonis..F.B.C. ,MI620.4., <br /> 15. Smoke detectors are to be installed:in-accordance with R313:1 of theT.B.C. :. <br /> 16.:.All glazing requirements are.to be"in accordance with R308.4.of the F.B.C. <br /> 17. All means"of egress are to be in accordance with R3I Lof the F.B.C. . <br /> 18. "Green gypsum board" shall riot be used:as.a backer in showers or tubs:R702:4:2.F.B.C. <br /> 19. Combination-type AFCI breakers.are,required,at all,locations requiring.an AFCLtype breaker: <br /> 20. Carbon monoxide.alarms will.be required in new:construction that uses fossil-burning heating <br /> .or appliances or an attached garage:__They shall be,installed in accordance with the V.B.C. <br /> 21. All plumbing, mechanical,:and electrical shall separate from unit to.unit. This"includes all . <br /> underground plumbing and electric: <br /> 22. All 20l l.N.E.C: Codes.Will be enforced:. <br /> 23:Tamper= Resistant Receptacles in accord with 406.11 of the 2011 N.E:C <br /> 24An accordance.with the Land.Development:Code;lots.shall be sodded before final of leash 10 <br /> febt'around the.9tr 0ture: <br /> 25'A.copy of the energy"cacls shall be with permit at all'thnes. <br /> - 26.:Copy of Inal insulation'report shall be.yrovided with.permit before.fznaL <br /> F.F.E.=Finished Floor.Elevation <br /> F.B.C_-Florida Building Code 6t'.Edition <br /> R.O.W.-Right-of Way <br /> A.D.A.-Americans-with.Disabilities Act N.E.C.-National.Electric Code (2011): . <br />
The URL can be used to link to this page
Your browser does not support the video tag.