Laserfiche WebLink
When Buildings Talk.We Listen. <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING <br /> CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and Performance Method <br /> Project Name: (p p Builder Name: L.P-n r yn p_S <br /> ! Street: (el&5R we'90n T-M J 5(-fe-f- Permit Office: <br /> City, State,Zip: Z-tp),y rh 1115 I=�� 33 Permit.Numb r: 0-0 <br /> Design Location: Jurisdiction: <br /> Envelope Leakage Test Results <br /> Single Point Test Data: ` <br /> HOUSE PRESSURE: U^� FLOW: �9 L <br /> Leakage Characteristics <br /> CFM(50): 1 LI ) Pass Fail <br /> ACH(50): 5,s <br /> R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air <br /> changes per hour in Climate Zones 1 and 2 ...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 <br /> Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals <br /> licensed as set forth in Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be <br /> signed by the party conducting the test and provided to the code officiate Testing shall be performed at any time after creation of all <br /> i penetrations of the building thermal envelope. <br /> 1-Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> Infiltration control measures; <br /> 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended <br /> infiltration control measures; <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off;and <br /> 6.Supply and return registers,If installed at the time of the test,shall be fully open <br /> - <br /> I hereby certify that the above envelope leakage Where required by the code official, testing shall be <br /> performance results demonstrate compliance with conducted by an approved third-party. A written report of <br /> Florida Energy Code requirements in accordance with the test results shall be signed by the third party <br /> section R402.4.1.2. conducting the test and provi to the code official. <br /> SIGNATURE: <br /> PRINTED NAME: i" 11ds`1 — IILDING Of1FI IAL: <br /> DATE: -7 01,201S _ DATE: g <br /> Testing was conducted In accordance with ANSI/RESNET/ICC 380 to meet the 2017 residential.energy code. <br />