Manual S Compliance Report Job: 2575B sf ADS <br /> Date: 10/3012017 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 18450 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 3541 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21991 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 116% of load <br /> Latent capacity: 3780 Btuh 107% of load <br /> Total capacity: 25200 Btuh 115% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 170% of load Capacity balance: 17 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. <br /> C Wrl htSOft° 2017-Oct-30 08:11:02 <br /> 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 <br /> ...A27UHE AH's\257513 sf ADS template 1.5 2 ton.rup Calc=MJB Front Door faces: W <br />