When B.ilm= w^We Lmt... <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING <br /> CONSTRUCTION <br /> Envelope Leakage Test Report <br /> Prescriptive and|PerfornnanceMethod <br /> Project Name: /_0 Builder Name: <br /> street: _52-7e) Permit Office: <br /> City, State, Zip: 172FIWkwncs 1(-t Permit Number: <br /> Design Location: Jurisdiction: <br /> Envelope Leakage Test Results <br /> single Point Test Data: <br /> ._ x�-/) / <br /> . HOUSE PRESSURE: `�^ `~ - ' FLOW: <br /> Leakage <br /> Characteristics <br /> Vpass / /F8U(� K8/5O\: �—� <br /> ACH(5O): <br /> R402A'1'2Teetiw0. The building o,dwelling unit shall he tested and verified cs having amair leakage rate of not exceeding 7air <br /> changes per hour in Climate Zones I and 2 ... Testing shall be conducted with a blower doorat a pressure of 0.2 inches w.g. (5V <br /> Pascals). Testing uho|| be conducted by either individuals as defined in Section 553.993(5) ory1. Florida Statutes orindividuals <br /> licensed as set forth in Section 489.105(3)(D, (g), or(1)or an approved third party.A written report of the results of the test shall be <br /> signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all <br /> penetrations of the building thermal envelope. <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other <br /> Infiltration control measures; <br /> o. Dampers ipdmuino exhaus, intake, makeup air, uacxun,ft and flue dampers shall be moseu, but not sno|eu beyond intended <br /> infiltration control measures; <br /> 3.Interior doors,J installed at the time o{the test,shall boopen; <br /> 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off-,and <br /> 0.Supply and return registers,if installed at the time uYthe test,shall he fully open <br /> | hereby certify that the above envelope leakage Where required by the code official, testing shall be <br /> performance results donnonmbab* compliance with conducted by an approved third-party. A written report of <br /> Florida Energy Code requirements in accordance with the test results shall be signed by the third party <br /> section R4O2412 <br /> PRINTEDNAME: BUILDING LFFM61AL <br /> 4, 1 1/ - - V <br /> DATE: DATE: <br /> Testing was conducted In accordance with ANSI/RESNET/ICC 380 IoVnel the 2017 residential enarg"y code. <br /> ---'' <br /> ������ <br />