Laserfiche WebLink
GENERAC® <br /> 16/20/22 kW specifications <br /> Generator CM <br /> G007035-0,G007036-0, G007038-0,G007039-0 G007042-0,G007043-0 <br /> Model G007037-0(16 klfl (20 MY) 2 I} <br /> Rated Maximum Continuous Power Cap acity_(LP.) _ 16,000 Wafts* 20,000 Watts 22,000 Watts" <br /> Rated Maximum Continuous Power Capacity(NG) 16,000 Wafts* 18,000 Watts* 19,500 Watts* <br /> ER ate Voltage I 240 240 _' _ _ 240 _ <br /> Rated Maximum Continuous Load Current-240 Volts(LP/NG) 66,6/66.6 83.3/75 91.6/81.3 <br /> Total Harmonic Distortion Less than 5% LESS than 5% Lees than 5% :77] 3 of <br /> Main Line Circuit Breaker 70 Amp 100 Amp 100 Pha Amp <br /> se - <br /> Number of Rotor Poles 2 2 2 <br /> Rated AC Fre uenay, 60 Hz '+ 60 Hz 60 Hz <br /> Power Factor 1.0 1.0 1.0 <br /> I3attery.Requjrement not included) _V 12 Volts,Group 26R 540 C_CA_Mi_nimum or Group 35AGM 6.50 CCA Minimum <br /> Unit Weight(Ib/kg) 409/186 448203 466/211 <br /> Dimensions(_x W x'HH)iNmm _ 48 x 25 x 29/1218 x 638 x 732 t <br /> Sound output in dB(A)at 23 It(7 m)with generator operating at normal load** 66 66 67 <br /> Y;Sound output-in dB(A)at 23 It(7 m)with gee <br /> nerator In 0uiet Test'"low-speed - 58" 58 ,�56 , <br /> ext -ercise mode— <br /> Exercise duration 5 min 5 min 5 min <br /> Engine <br /> T per of Engine�� g - — 7 GENERAC OHVI V-TWIN GENERAC OHVI VTWIN _GENE_RACOH_VIIVV_—T_W_IN_"",-'� <br /> Number of Cylinders 2 2 2 <br /> Displacement cc 999,cc '999 cc <br /> Cylinder Block Aluminum w/Cast Iron Sleeve <br /> �alve'Arrangement Overhead Valve Overhead Valve _ Overhead Valve <br /> Ignition System _ Solid-state w/Magneto Solid-state w/Magneto Solid-stale w/Magneto <br /> Governor System_ _ A _ Electronic Electronic Electronic <br /> Compression Ratio 9.5:1 9.5:1 9.5:1 <br /> ,Starter �� -�,12Vda 1ZVdc__ m'12Vdc <br /> Oil Capacity Including Filter Approx.1.9 gV1.8 L Approi 1.9 gV1.8 L Approx.1.9 gt/1.8 L <br /> 0 eratin r m _. 3,600 3,600_ _- 3,600 4 i .P 9�p <br /> Fuel Consumption <br /> Natural Gas ft3/hr(ma/hr) <br /> 12 Load 193(5.47) 205(5.8) 184(5.21) <br /> Full Load 312(8.83) 308(8.72) 281(7.96) <br /> Liquid Propane O/hr(gal/hr)[I/hr] <br /> 12 Load 69(1.9)[7.2] 81(2.23)[8.45] 78(2.16)[8.16] <br /> Full Load ":. 116(3.19)112.07] 140(3.85)[14.571 134(3.68)[13.94] <br /> -Note:Fuel pipe musl6e sized for lull bad. Requcted'fuel•pressrire to generator fuel inlet a[all loadianges-3.5-7°water column(7-13 mm mercury)focnatural gas,10-12"water column(19-22 rnm <br /> merou for LP gas.For Btu content,mulli&fC3/hr x 2500(LP)or.(t3/hrx'1000(NG).For Megajoule content;multiply m3/hr z 93.15(lP)or m3/hrx 37.26(NG)_ - <br /> Controls <br /> 2-Line.Plain Text Multilingual LCD DisplaySimple user interlace for ease of operation. <br /> Mode Buttons: Auto Automatic Start on Utility failure.7 day exerciser. <br /> Manual y� -Start with starter control,unit stays on.,H utility fails,transfer to load_takes_place. <br /> Off _ Slops unit.Power is removed.Control and charger still operate. <br /> [Ready to Run(Mainlenahce Messages Standard 77"7 <br /> Engine Run Hours Indication Standard <br /> Programrnableslad delay.betiveen2-1500 seconds— ' ' Slandad'(progmnxnable by dealer on{y) <br /> UlililyVoltage Loss/Relum to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V <br /> Future.Sel CaCapable Eterciser/Exercise Set Error Warning _ _ Standard <br /> Run/Alarmt(Mainlenance Logs _ _ 50 Events Each <br /> Engine Start Sequence _Cyclic cranking:l6 sec on,7 rest(It sec ma>omum duration). � 4 D <br /> Starter_Lock-out Starter cannot re-engage until 5 sec after engine has stopped. <br /> Smart Battery Changer; wSlandard <br /> Charger Faull/Missing AC Warning Standard _ <br /> lr,Low Batlery/Battery Problem Protection and Gallery Condition Indication, =' .. '� ' . '• ` '- Standard .:. � -' �? --�-�--'�.� <br /> Automatic Voltage Regulation with Over and UnderVoltage Protection Standard <br /> Under-Frequency/Ovedoad/Steppe r Overcunenl Prole_ction__ _ Standatd ----- <br /> Safety Fused/Fuse Problem Protection Standad <br /> Automatic Low Oil Pressure/High Oil Temperature Shuldovm= Standard <br /> Overcrank/Overspeed(Q 72 Hz)/rpm Sense Loss Shutdown Standard <br /> a,High Engine Temperature Shutdown Standad <br /> Internal Fault/Incorrect Wiring Protection Standard <br /> bommo E emalFaultCapa_bility Standard' <br /> Field Upgradable Firmware Standard <br /> "Sound levels are taken from he front of the generator.Sound levels taken tom older sides of the generator maybe higher depending on instillation parameters.Rating definitions-Standby Applicable for supplyng emergency power for the duration <br /> or me utility power outage.No overload capability is available for this rating (All ratings in accordance with BS5514,IS03M and OI%271).*Maximum wattage aid current are subject to and limited by such factors as fuel BWAnappule content, <br /> armienl lempealure,altitude,engine power and condition,etc.Madmnen power decreases about 3.5 parent fa each 1.000 feet(304.8 meters)above sea level:aid alsowll decrease about 1 percent for each 6`C(10'0 above 16"C(60 9. <br />