Laserfiche WebLink
f <br /> l <br /> GENERAC® <br /> 16/20/22 kW switch options <br /> Limited Circuit,Switch Model 0007036-0(16IrW) <br /> • 16 circuits. No,of Poles _ _ 2 <br /> Current Rating-(Amps) . 1 100 <br /> • Electrically operated,mechanically-held contacts for fast,positive connections. V I age Rating_(VAC)u_ 120/240/10 <br /> •Rated for all classes of load, 100%equipment rated,both inductive and resistive. Utility voltage Monitor(Fixed)'Y <br /> -Pick-up 80% <br /> • 2 pole,250 VAC contactors. -Dropout 65% <br /> • 30 millisecond transfer time. fRetum to utility'__ ___- approx.l5 sec. <br /> Exercise bi-weekly for 12 minutes" Standard <br /> •Dual coil design. IUL Listed standard , <br /> Total of Pre-wired Circuits 16 <br /> • Rated for both copper and aluminum conductors. No.15 A 120 V 5 <br /> • Main contacts are silver plated or silver alloy to resist welding and sticking. No.20 A 0 V 5 <br /> 24 <br /> No.20 A 240 V 1 <br /> • NEMA 311 aluminum outdoor enclosure allows for indoor or outdoor mounting No.30 A 240 V - <br /> flexibility. No.40 A 240 V 1 <br /> No.50 A 240 V 1 <br /> • Multi listed for use with 1"standard,tandem,GFCI and AFCI breakers from ;Tandem Brea Breaker Capability 8 spaces <br /> Siemens,Murray,Eaton and Square D for the most flexible and cost effective install. Circuit Breaker Protected� � <br /> Available RMS Symmetrical <br /> Fault Current @ 250 Volts 10,000 <br /> "Function of Evolution Controller <br /> Exercise can be set to weekly or monthly <br /> Dimensions 200 Amps 120/240,1e W' <br /> Open Transition Service Rated <br /> Height Width pepth <br /> H1 H2 W1 W2 <br /> in 27.24 30.0 11.4 13.5 7.09 Ht H <br /> mm 692.0 762.4 289.0 343.0 180.0 <br /> Wire flames <br /> Conductor Lug Neutral Lug Ground Lug <br /> 210-#14 2/0-#14 2/0-#14 o�H W2 J <br /> Service Rated Smart Switch Features .1 1kW)/G00703910 <br /> •Includes Digital Power Management Technology standard(DPM). Memel �(`i607043-0(22 IrW)� <br /> • Intelligently manages up to four air conditioner loads with no (No.of Poles _J _ 2 � <br /> additional hardware. Current Rating(Amps)) 200 <br /> 'Voltag R t ng(VAC) _ 1zo2ao,1Q <br /> • Up to four more large(240 VAC)loads can be managed when used in Utility Voltage Monitor(Fixed)' <br /> conjunction with Smart Management Modules(SMMs). -Pick-up 80% <br /> • Electrically operated,mechanically-held contacts for fast,clean -Dropout 65% <br /> connections. [Return to UtilityY*� __- _ apnrox 13 <br /> • Rated for all classes of load,100%equipment rated,both inductive and Exercise weekly for 12 minutes` Standard <br /> resistive. IULListed a StandardEnclosure _ <br /> • U to four more large 120/240 VAC loads can be managed when used in <br /> Type NEMANL 3R <br /> P 9 ( ) 9 Withstand Rating_(Amps)_ 22,0110 <br /> conjunction with 50 amp Power Management Modules(PMM"). Lug Range 250 MCM-#6 <br /> • 2 pole,250 VAC contactors. 'Function of Evolution Controller <br /> •Service equipment rated,dual coil design. <br /> • Rated for both aluminum and copper conductors. W, <br /> • NEMA 3R aluminum outdoor enclosure allows for indoor or outdoor <br /> mounting flexibility. <br /> • Main contacts are silver plated or silver alloy to resist welding and <br /> sticking. <br /> H2 H1 <br /> Dimensions 200 Amps 120/240,10 <br /> Open Transition Service Rated <br /> Height Width Depth <br /> H1 H2 Wt I W2 <br /> in 27.24 30.0 11.4 13.5 7.09 <br /> mm 692.0 762.4 289.0 343.0 180.0 °EPTM F —u <br />