Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: /Hayden 2605 Elev C i _/_ Builder Name: DRH Expryss Homes <br /> Street: lD IJ �>dn�r�?i u / Permit Office: ` 7R_Pn ("( <br /> City,State,Zip: Zephyrhills, FL, Permit Number: 14 <br /> 1 6 <br /> Owner: M50 Jurisdiction: (D-tt(pab <br /> Design Location: FL,Tampa \ County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area <br /> 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=11.0 1285.30 ft2 <br /> b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Windows(250.0 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 .SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.052 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8. Floor Types (1541.0 sg a.Electric Cap:50 gallons <br /> ft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ft2 None <br /> c.N/A R= ft2 - 15.Credits Pstat <br /> Glass/Floor Area: 0.096 F��7CS <br /> Total Proposed Modified Loads: 78.39 PASS <br /> Total Baseline Loads: 79.15 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and J'V14E ST,gx <br /> this calculation are in compliance with the Florida Energy specifications covered by this `_ p <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. N rrr„ ::: ;;\•° „ <br /> PREPARED BY: Before construction is completed u�3 <br /> DATE: n-g-n this buildingwill be inspected for <br /> a <br /> P c➢ r°l; �► <br /> compliance with Section 553.908 * ° <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. �i flD yyT,'� <br /> OWNER/AGENT:� BUILDING OFFICIAJ�: !/ <br /> DATE: / �V DATE: _(" �S'l <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 On for whole house. <br /> 1 1/9/201 7 9:57 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />