Laserfiche WebLink
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes <br /> Street: 6_ Permit Office: <br /> City,State,Zip: Zephyrhills,FL I k <br /> Permit Number: <br /> Owner: 4 Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 <br /> i New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1285.30 ft2' <br /> -b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=1 1.0 332.22 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= ft2 <br /> 10.Ceiling Types (1541.0 sqft.) Insulation Area " <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 <br /> N/A <br /> Conditioned floor area below grade(ft2) 0 c.11. Duct R= ft2 <br /> s R ft2 <br /> 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,U=0.34 210.00 ft2 <br /> SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 a.Central unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.052 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> 8, Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Ed EF:0.950 <br /> ge Insulation R=0.0 1104.00 ft2 b. Conservation features <br /> b.Raised Floor 11=19.0 437.00 ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0,096 Total Proposed Modified Loads: 78.39 PASS <br /> Total Baseline Loads: 79.15 <br /> 0 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance 'o <br /> with the Florida Energy Code. 0 <br /> PREPARED BY: 4 Before construction is completed <br /> DATE: this building will be inspected for 0 7­ P41- <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. WE <br /> OWNER/AGENT- f���L.��T��-- BUILDING PFFI IAL: <br /> DATE: DATE: 4� <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. I <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is riot greater than 0.050 Qn for whole house. <br /> 11/9/2017 9:57 AM EnergyGauge(D USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />