My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19709
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19709
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 1:49:18 PM
Creation date
2/7/2019 1:49:15 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19709
Building Department - Name
DR HORTON INC
Address
6504 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Cali 1828 El'ev D� ._\ I ( Builder Name: DR ExpHorrtes `� <br /> Street: �-jt� J Permit Office: CI P7�Il iu <br /> City,State,Zip: %pphyrhills,FL,`�J��� /I ( Permit Number:�Q 70,9 <br /> Owner: 5s � ( Jurisdiction: <br /> Design Location: FL,Tampa ` County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction of existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftz <br /> 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c. R= ftz <br /> 11. Duct <br /> s R ftz <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.091 f1a7�7ASS Total Proposed Modified Loads: 60.72 P <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and "SKE ST,q? <br /> this calculation are in compliance with the Florida Energy specifications covered by this _ 4_1 pit <br /> Code. calculation indicates compliances+ <br /> A with the Florida Energy Code. Jrrrrr�'r:•';: .`�';,,r <br /> PREPARED BY: cs[ Before construction is completed t7 <br /> DATE: a-a-n this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. 4. <br /> with the Florida Energy Code. GAD WE�g�1 <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: l�' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 11/9/2017 10:39 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.