My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-19709
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-19709
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 1:49:18 PM
Creation date
2/7/2019 1:49:15 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
18-19709
Building Department - Name
DR HORTON INC
Address
6504 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION- <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Call 1828 Elev D Builder Name: DRH Express Homes <br /> (�""< I Permit Office: <br /> Street: 'zc" ��pa <br /> o t I ud' ' �q'l' ' <br /> City,State,Zip: ��e-p.hyr.hil ,FL, Permit Number: <br /> Owner: lT Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 <br /> I New construction or existing New(From Plans) .9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1- 1404.00 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 306.22 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned floor area above grade(W) 1828 b.N/A J R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11. Ducts R ft2 <br /> 7. Windows(I 66.5 scift.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: DbI,U=0.55 40.00 112 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0,317 14. Hot water systems <br /> 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.72 PASS <br /> Total Baseline Loads: 61.25 <br /> I hereby certify that the plans and specifications covered by Review of the plans and iES7.'-J <br /> this calculation are in compliance with the Florida Energy specifications covered by this <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: L c .. Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. SOD WE <br /> OWNER/AGENT"' ',: � BUILDING Q' FFICIAL A2� <br /> DATE: DATE: <br /> - C6inpliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 On for whole house. <br /> 11/9/2017 10:39 AM EnergyGauge@ USA-FIaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.